Influence of Air Temperature Change on Equilibrium Velocity of Pneumatic Cylinders
Authors:
- 10 May 2002
- journal article
- Published by ASME International in Journal of Dynamic Systems, Measurement, and Control
- Vol. 124 (2) , 336-341
Abstract
This paper shows that equilibrium velocity of pneumatic cylinders not only depends on the effective area of the outlet speed control valve but also on the air temperature at the discharge chamber. Different equilibrium velocities were obtained experimentally with the same speed control valves, when load mass or initial pressure at the discharge chamber was changed. The different equilibrium velocities are explained by the air temperature change. Experiments are simulated using a cylinder model considering heat transfer. Experimental and simulation results are in good agreement.Keywords
This publication has 4 references indexed in Scilit:
- Heat Transfer Effects on the Frequency Response of a Pneumatic Nozzle FlapperJournal of Dynamic Systems, Measurement, and Control, 1985
- Study on the temperature characteristics of a pneumatic cylinder system (Part1, Experimental investigation)Hydraulics & Pneumatics, 1985
- Thermal Damping in Gas-Filled Composite Materials During Impact LoadingJournal of Applied Mechanics, 1970
- The Analysis and Design of Pneumatic SystemsJournal of Applied Mechanics, 1967