Accuracy of Consumer Monitors for Estimating Energy Expenditure and Activity Type
Authors:
- Scott E. CrouterSCScott E. Crouter
- David R. BassettDBDavid R. Bassett
- Eugene C. FitzhughEFEugene C. Fitzhugh
- William R. BoyerWBWilliam R. Boyer
- 1 February 2017
- journal article
- research article
- Published by Wolters Kluwer Health in Medicine & Science in Sports & Exercise
- Vol. 49 (2) , 371-377
Abstract
Increasing use of consumer-based physical activity (PA) monitors necessitates that they are validated against criterion measures. Thus, the purpose of this study was to examine the accuracy of three consumer-based PA monitors for estimating energy expenditure (EE) and PA type during simulated free-living activities. Twenty-eight participants (mean ± SD: age, 25.5 ± 3.7 yr; body mass index, 24.9 ± 2.6 kg·m−2) completed 11 activities ranging from sedentary behaviors to vigorous intensities. Simultaneous measurements were made with an Oxycon portable calorimeter (criterion), a Basis Peak and Garmin Vivofit on the nondominant wrist, and three Withings Pulse devices (right hip, shirt collar, dominant wrist). Repeated-measures ANOVA were used to examine differences between measured and predicted EE. Intraclass correlation coefficients were calculated to determine reliability of EE predictions between Withings placements. Paired samples t tests were used to determine mean differences between observed minutes and Basis Peak predictions during walking, running, and cycling. On average, the Basis Peak was within 8% of measured EE for the entire PA routine (P > 0.05); however, there were large individual errors (95% prediction interval, −290.4 to +233.1 kcal). All other devices were significantly different from measured EE for the entire PA routine (P < 0.05). For activity types, Basis Peak correctly identified ≥92% of actual minutes spent walking and running (P > 0.05), and 40.4% and 0% of overground and stationary cycling minutes, respectively (P < 0.001). The Basis Peak was the only device that did not significantly differ from measured EE; however, it also had the largest individual errors. Additionally, the Basis Peak accurately predicted minutes spent walking and running, but not cycling.Keywords
This publication has 25 references indexed in Scilit:
- Accuracy of the vivofit activity trackerJournal of Medical Engineering & Technology, 2016
- Comparison of Consumer and Research Monitors under Semistructured SettingsMedicine & Science in Sports & Exercise, 2016
- Fitbit®: An accurate and reliable device for wireless physical activity trackingInternational Journal of Cardiology, 2015
- The validity of consumer-level, activity monitors in healthy adults worn in free-living conditions: a cross-sectional studyInternational Journal of Behavioral Nutrition and Physical Activity, 2015
- Are Currently Available Wearable Devices for Activity Tracking and Heart Rate Monitoring Accurate, Precise, and Medically Beneficial?Healthcare Informatics Research, 2015
- Monitoring Daily Function in Persons With Transfemoral Amputations Using a Commercial Activity Monitor: A Feasibility StudyPM&R, 2014
- Refined Two-Regression Model for the ActiGraph AccelerometerMedicine & Science in Sports & Exercise, 2010
- Using Pedometers to Increase Physical Activity and Improve HealthJAMA, 2007
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- A Biometric Study of Human Basal MetabolismProceedings of the National Academy of Sciences, 1918