Cemented conical stems can be removed more easily than cylindrical stems, regardless of cone angle in revision knee arthroplasty
- 1 December 2018
- journal article
- research article
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 138 (12) , 1747-1754
Abstract
According to literature, more than 30% of revised knee arthroplasties will require at least one re-revision. Practical experience has shown that there are considerable product-specific differences in the explantability of cemented long-stem prostheses. In the registers of successful implants, stem geometry varies considerably between the manufacturers. However, comparative data on explantability of the respective stems are missing. Objective of the present study was to identify a correlation between the geometry of a smooth cemented long stem and the necessary explantation energy required until failure of the implant-cement interface occurs. Eight cemented stems with different conical profile angles (0A degrees-3A degrees) were explanted in a reproducible biomechanical setup each six times to evaluate the correlation between the stem design and the required explantation energy. The average explantation energy was highest in the case of the cylindrical stem, at 18.1 +/- 3.6 J. At a cone angle of 0.25A degrees, it was just 12.1 +/- 2.1 J (p < 0.001) and dropped beyond 0.5A degrees to an average of 5.7 +/- 1.8 J (p < 0.001). Between 0.5A degrees and 3A degrees, no significant difference in the required extraction energy was observed. Whereas smooth conical stems can mostly be removed easily, an early decision in favour of osteotomy or fenestration can be taken in the case of cylindrical cemented stems.Keywords
This publication has 62 references indexed in Scilit:
- Systematic Review Comparing Static and Articulating Spacers Used for Revision of Infected Total Knee ArthroplastyThe Journal of Arthroplasty, 2014
- Risk Factors for Total Knee Arthroplasty Aseptic RevisionThe Journal of Arthroplasty, 2013
- Cement-Implant Interface Contamination: Possible Reason of Inferior Clinical Outcomes for Rough Surface Cemented StemsThe Open Orthopaedics Journal, 2013
- Reinfection after two-stage revision for periprosthetic infection of total knee arthroplastyInternational Orthopaedics, 2011
- Future Young Patient Demand for Primary and Revision Joint Replacement: National Projections from 2010 to 2030Clinical Orthopaedics and Related Research, 2009
- Outcome of a Second Two-stage Reimplantation for Periprosthetic Knee InfectionClinical Orthopaedics and Related Research, 2009
- Results of Press-fit Stems in Revision Knee ArthroplastiesClinical Orthopaedics and Related Research, 2009
- Projections of Primary and Revision Hip and Knee Arthroplasty in the United States from 2005 to 2030Journal of Bone and Joint Surgery, 2007
- Revision Total Knee ArthroplastyClinical Orthopaedics and Related Research, 2002
- Long-term Results after Total Condylar Knee ArthroplastyClinical Orthopaedics and Related Research, 1987