Efficacy of three different rotary files to remove gutta‐percha and Resilon from root canals
- 19 August 2010
- journal article
- research article
- Published by Wiley in International Endodontic Journal
- Vol. 43 (11) , 1022-1028
Abstract
To evaluate the efficacy of ProTaper Retreatment files, Mtwo Retreatment files and Twisted Files for removal of gutta-percha and Resilon in straight root canals. Ninety single root canals were instrumented and randomly allocated into 6 groups of 15 specimens each with regards to the filling material and instruments used. Group 1: gutta-percha/ProTaper; Group 2: Resilon/ProTaper; Group 3: gutta-percha/Mtwo; Group 4: Resilon/Mtwo; Group 5: gutta-percha/Twisted Files; Group 6: Resilon/Twisted Files. For all roots, the following data were recorded: procedural errors, duration of retreatment, canal wall cleanliness through optical microscope and cone beam computed tomography (CBCT). Data were statistically analysed, and the level of significance was set at P=0.05. No system completely removed the root filling material from root canal walls. No significant differences were observed between the rotary systems in terms of the area of filling material left within the canals (P>0.05). There were statistically significant differences between the filling materials: Resilon/Real Seal had less residual material than gutta-percha/AH plus (CBCT: P=0.01; microscope: P=0.018). Mtwo Retreatment files were more rapid when removing filling material than ProTaper Retreatment files (P=0.19) and Twisted Files (P=0.04). No system removed the root filling materials entirely. Mtwo Retreatment files required less time to remove root filling material than the other instruments. Resilon was removed significantly better from the canal walls than gutta-percha, irrespective of the rotary instruments used.Keywords
This publication has 26 references indexed in Scilit:
- New dimensions in endodontic imaging: part 1. Conventional and alternative radiographic systemsInternational Endodontic Journal, 2009
- New dimensions in endodontic imaging: Part 2. Cone beam computed tomographyInternational Endodontic Journal, 2009
- A comparison of the efficacy of conventional and new retreatment instruments to remove gutta‐percha in curved root canals: an ex vivo studyInternational Endodontic Journal, 2009
- Mechanical properties of a new and improved nickel-titanium alloy for endodontic use: an evaluation of file flexibilityOral Surgery Oral Medicine Oral Pathology Oral Radiology and Endodontology, 2008
- Efficacy of ProTaper Universal rotary retreatment system for gutta‐percha removal from root canalsInternational Endodontic Journal, 2007
- Efficacy of three rotary NiTi instruments in removing gutta‐percha from root canalsInternational Endodontic Journal, 2007
- Retreatment efficacy of the Epiphany soft resin obturation systemInternational Endodontic Journal, 2007
- Effectiveness of two nickel‐titanium rotary instruments and a hand file for removing gutta‐percha in severely curved root canals during retreatment: an ex vivo studyInternational Endodontic Journal, 2007
- Efficacy of automated versus hand instrumentation during root canal retreatment: an ex vivo studyInternational Endodontic Journal, 2006
- Effectiveness of different techniques for removing gutta‐percha during retreatmentInternational Endodontic Journal, 2004