A review: taking the sterile out of sterility
Author:
Open Access
- 1 December 1999
- journal article
- review article
- Published by Oxford University Press (OUP) in Journal of Applied Microbiology
- Vol. 87 (6) , 789-793
Abstract
Users of in‐dwelling medical devices, prostheses and surgical dressings rely implicitly on their sterility. Rarely do consumers give any thought to what sterility really means. The general assumption is that manufacturers have adopted the most efficient and cost‐effective methods of achieving sterility. Currently, terminal sterilization processes appropriate for the manufacture of medical devices are those that are deemed to give less than one chance in a million of a single, finished product item containing a viable organism. Such a definition of sterility is embodied in the European standard EN556 as a Sterility Assurance Level of 10−6, based on the properties of heat‐resistant endospores. However, is this level of sterility assurance appropriate for all categories of medical device? Moreover, do all medical devices which are labelled as sterile require the same level of treatment? This paper will demonstrate that in some instances, the high standards set for sterilization processing are unreasonable, not cost‐effective and exclude new sterilization technologies from being accepted by the regulatory authorities.Keywords
This publication has 10 references indexed in Scilit:
- Glutaraldehyde‐resistant Mycobacterium chelonae from endoscope washer disinfectorsJournal of Applied Microbiology, 1997
- Microwave plasmas for low-temperature dry sterilizationBiomaterials, 1996
- Low-Temperature Sterilization Technologies: Do We Need to Redefine "Sterilization"?Infection Control & Hospital Epidemiology, 1996
- Modification by surface association of antimicrobial susceptibility of bacterial populationsJournal of Industrial Microbiology and Biotechnology, 1995
- Effectiveness of ethylene oxide for sterilization of dental handpiecesJournal of Dentistry, 1995
- Increasing the probability of sterility of medicinal productsJournal of Pharmacy and Pharmacology, 1977
- Nationwide epidemic of septicemia caused by contaminated intravenous productsThe American Journal of Medicine, 1976
- Improvement of solubility and dissolution rate of poorly water-soluble salicylic acid by a spray-drying techniqueJournal of Pharmacy and Pharmacology, 1975
- Sepsis Caused by Contaminated Intravenous FluidsAnnals of Internal Medicine, 1972
- THE TESTING OF STERILISERSThe Lancet, 1958