Wearable Magnetic Flexonic Sensor Nodes for Simultaneous Normal Force and Displacement Measurements
- 25 October 2022
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 7 (4) , 12331-12338
Abstract
Illustrated in the context of home-based stroke rehabilitation, this paper presents the design and development of magnetic flexonic sensor nodes (FSNs) with configurable parameters for simultaneous sensing of normal forces and displacement. The FSN is composed of a magnetic sensor in flexible elements that can be embedded in wearable devices and rapid-prototyped at a low cost to facilitate distributed force sensing applications. As an illustration, a shoe insole with 19 embedded FSN for monitoring the plantar force distribution and arch height has been designed, prototyped, and experimentally evaluated by comparing it with a commercial dynamometric platform. The FSN-embedded insole directly measures the arch height and captures the transients of the plantar forces in five different zones in real-time. Because of the simplicity and low cost, FSNs have the potential to facilitate fabricating low-cost sensing systems, for example, for home-based stroke rehabilitation where the insole stiffness and arch height of the embeddable electronic sensors can be configured according to the patient's specific abnormal plantar distribution to adapt to different range and distribution and wearable configuration during different rehabilitation state.Keywords
Funding Information
- National Key R&D Program of China (2021YFB3200700)
- National Natural Science Foundation of China (U1713204, 52175510, 52188102)
- Young Elite Scientists Sponsorship Program
- CAST (2019QNRC001)
This publication has 30 references indexed in Scilit:
- Magnetic Tensor Sensor for Gradient-Based Localization of Ferrous Object in Geomagnetic FieldIEEE Transactions on Magnetics, 2016
- Effects of custom‐made textile insoles on plantar pressure distribution and lower limb EMG activity during turningJournal of Foot and Ankle Research, 2016
- Use of Silicone Materials to Simulate Tissue Biomechanics as Related to Deep Tissue InjuryAdvances in Skin & Wound Care, 2015
- Validation and reliability testing of a new, fully integrated gait analysis insoleJournal of Foot and Ankle Research, 2015
- A study of structural foot deformity in stroke patientsJournal of Physical Therapy Science, 2015
- An Inductive Sensor for Real-Time Measurement of Plantar Normal and Shear Forces DistributionIEEE Transactions on Biomedical Engineering, 2014
- SIRRACTNeurorehabilitation and Neural Repair, 2014
- Dynamic plantar pressure parameters associated with static arch height index during gaitClinical Biomechanics, 2009
- A Gait Monitoring System Based on Air Pressure Sensors Embedded in a ShoeIEEE/ASME Transactions on Mechatronics, 2009
- The arch index: A useful measure from footprintsJournal of Biomechanics, 1987