Effect of Increasing Pump Speed During Exercise on Peak Oxygen Uptake in Heart Failure Patients Supported with a Continuous-Flow Left Ventricular Assist Device. A Double-Blind Randomized Study
Open Access
- 8 January 2014
- journal article
- research article
- Published by Oxford University Press (OUP) in European Journal of Heart Failure
- Vol. 16 (4) , 403-408
Abstract
Aims Continuous‐flow left ventricular assist device (CF‐LVAD) implantation is associated with improved quality of life, but the effect on exercise capacity is less well documented. It is uncertain whether a fixed CF‐LVAD pump speed, which allows for sufficient circulatory support at rest, remains adequate during exercise. The aim of this study was to evaluate the effects of fixed versus incremental pump speed on peak oxygen uptake (peak VO2) during a maximal exercise test. Methods and results In CF‐LVAD (HeartMate II) patients exercise testing measuring peak oxygen uptake (VO2) was performed on an ergometer bike twice in one day: once with fixed pump speed (testfix) and once with incremental pump speed (testinc). The order of testfix and testinc in each patient was determined by randomization. During testinc pump speed was increased from the baseline value by 400 rpm/2 min. Fourteen patients (aged 23–69 years) were included with a mean support duration of 465 ± 483 days. Baseline CF‐LVAD speed was 9357 ± 238 rpm and during testinc speed was increased by a mean of 1486 ± 775 rpm. Mean peak VO2 was significantly higher in testinc compared with testfix (15.4 ± 5.9 mL/kg/min vs. 14.1 ± 6.3 mL/kg/min; P = 0.012), corresponding to a 9.2% increase. All exercise tests (n = 28) were adequately performed with RER > 1. Conclusion Increasing pump speed during exercise augments peak VO2 in patients supported with CF‐LVADs. An automatic speed‐change function in future generations of CF‐LVADs might improve functional capacity.Keywords
This publication has 26 references indexed in Scilit:
- Fifth INTERMACS annual report: Risk factor analysis from more than 6,000 mechanical circulatory support patientsThe Journal of Heart and Lung Transplantation, 2013
- Validation of the Innocor Device for Noninvasive Measurement of Oxygen Consumption in Children and AdultsPediatric Cardiology, 2012
- Relationship Between Pump Speed and Exercise Capacity During HeartMate II Left Ventricular Assist Device Support: Influence of Residual Left Ventricular FunctionEuropean Journal of Heart Failure, 2012
- Monitoring tissue oxygenation by near infrared spectroscopy (NIRS): background and current applicationsJournal of Clinical Monitoring and Computing, 2012
- Central and Peripheral Blood Flow During Exercise With a Continuous-Flow Left Ventricular Assist DeviceCirculation: Heart Failure, 2011
- The impact of acute reduction of continuous-flow left ventricular assist device support on cardiac and exercise performanceHeart, 2010
- Continuous Flow Left Ventricular Assist Device Improves Functional Capacity and Quality of Life of Advanced Heart Failure PatientsJACC, 2010
- Clinical management of continuous-flow left ventricular assist devices in advanced heart failureThe Journal of Heart and Lung Transplantation, 2010
- Reliability of Measurements with InnocorTMduring ExerciseInternational Journal of Sports Medicine, 2009
- Long-Term Use of a Left Ventricular Assist Device for End-Stage Heart FailureNew England Journal of Medicine, 2001