Estimation and Tracking of AP-diameter of the Inferior Vena Cava in Ultrasound Images Using a Novel Active Circle Algorithm
Authors:
Preprint
Abstract
Medical research suggests that the anterior-posterior (AP)-diameter of the inferior vena cava (IVC) and its associated temporal variation as imaged by bedside ultrasound is useful in guiding fluid resuscitation of the critically-ill patient. Unfortunately, indistinct edges and gaps in vessel walls are frequently present which impede accurate estimation of the IVC AP-diameter for both human operators and segmentation algorithms. The majority of research involving use of the IVC to guide fluid resuscitation involves manual measurement of the maximum and minimum AP-diameter as it varies over time. This effort proposes using a time-varying circle fitted inside the typically ellipsoid IVC as an efficient, consistent and novel approach to tracking and approximating the AP-diameter even in the context of poor image quality. In this active-circle algorithm, a novel evolution functional is proposed and shown to be a useful tool for ultrasound image processing. The proposed algorithm is compared with an expert manual measurement, and state-of-the-art relevant algorithms. It is shown that the algorithm outperforms other techniques and performs very close to manual measurement.Keywords
All Related Versions
This publication has 24 references indexed in Scilit:
- pSnakes: A new radial active contour model and its application in the segmentation of the left ventricle from echocardiographic imagesComputer Methods and Programs in Biomedicine, 2014
- Multiscale geodesic active contours for ultrasound image segmentation using speckle reducing anisotropic diffusionOptics and Lasers in Engineering, 2014
- Cardiac variation of inferior vena cava: new concept in the evaluation of intravascular blood volumeJournal of Medical Ultrasonics, 2013
- Probability density difference-based active contour for ultrasound image segmentationPattern Recognition, 2010
- Kernel Density Estimation and Intrinsic Alignment for Shape Priors in Level Set SegmentationInternational Journal of Computer Vision, 2006
- Respiratory changes in inferior vena cava diameter are helpful in predicting fluid responsiveness in ventilated septic patientsIntensive Care Medicine, 2004
- The role of central venous pressure and type of vascular control in blood loss during major liver resectionsThe American Journal of Surgery, 2004
- A variational framework for integrating segmentation and registration through active contoursMedical Image Analysis, 2003
- Early Goal-Directed Therapy in the Treatment of Severe Sepsis and Septic ShockThe New England journal of medicine, 2001
- Snakes: Active contour modelsInternational Journal of Computer Vision, 1988