Root surface strain during canal shaping and its influence on apical microcrack development: a preliminary investigation
- 5 November 2014
- journal article
- research article
- Published by Wiley in International Endodontic Journal
- Vol. 48 (12) , 1103-1111
Abstract
Aim: To determine the root surface strain (RSS) generated during root canal shaping and its effects on apical microcrack development.Methodology: Twenty‐five extracted human mandibular premolars were selected and decoronated. The teeth were instrumented with either the ProTaper (PT) or WaveOne (WO) (Dentsply Maillefer) NiTi rotary systems (n = 10 per group) or used as controls (n = 5). Instrumented root canals were enlarged to ProTaper F4 (size 40, 0.06 taper) or using WaveOne LARGE (size 40, 0.08 taper) instruments according to the manufacturer's instructions. An electrical strain gage (KFG02‐120‐C1‐16, Kyowa Dengyo, Tokyo, Japan) was fixed on the proximal root surface and connected to a strain amplifier via a bridge box in order to measure RSS. During canal shaping, the strain output of the amplifier was recorded. The instantaneous RSS induced by each instrument and the maximum RSSs were determined. All teeth were then stained with contrast media and imaged with micro‐computed tomography (micro‐CT) at an isotropic resolution of 10 μm to detect microcracks. The mean maximum RSS values (microstrain) and mean number of microcracks recorded for both groups were tested for statistical significance using Mann–Whitney U‐test. Presence/absence of microcracks in both groups was compared by chi‐square tests.Results: Increased baseline RSS from strain accumulation during canal shaping was observed, with similar maximum RSS (mean ± SD) for PT (416.6 ± 185.1 μstrain) and WO (398.2 ± 163.8 μstrain) (P = 0.94). The interevaluator reliability for microcrack detection using micro‐CT had a kappa value of 0.998. Compared to the PT group, there was a trend for fewer samples with microcracks in the WO group (P = 0.051). On the micro‐CT images, apical microcracks were detected in 20 PT and 11 WO samples (P = 0.10). The microcracks were observed in the buccolingual direction in all WO and 81% of PT samples. No vertical root fractures were found. The maximum RSS obtained during canal shaping was poorly correlated with the number of microcracks found (R2 = 0.093).Conclusions: Based on these preliminary data, canal shaping appears to cause apical microcracks regardless of the type of rotary instrument motion. Contrast‐enhanced micro‐CT was able to identify microcracks in roots.Keywords
This publication has 44 references indexed in Scilit:
- Apical surgery: endoscopic findings at the resection level of 168 consecutively treated rootsInternational Endodontic Journal, 2011
- Extended cyclic fatigue life of F2 ProTaper instruments used in reciprocating movementInternational Endodontic Journal, 2010
- The effect of irrigation time, root morphology and dentine thickness on tooth surface strain when using 5% sodium hypochlorite and 17% EDTAInternational Endodontic Journal, 2010
- Detection of dentinal cracks using contrast-enhanced micro-computed tomographyJournal of the Mechanical Behavior of Biomedical Materials, 2010
- The effects of canal preparation and filling on the incidence of dentinal defectsInternational Endodontic Journal, 2009
- Influence of instrument taper on the resistance to fracture of endodontically treated rootsOral Surgery Oral Medicine Oral Pathology Oral Radiology and Endodontology, 2006
- Comparative study of six rotary nickel–titanium systems and hand instrumentation for root canal preparationInternational Endodontic Journal, 2005
- Mechanical preparation of root canals: shaping goals, techniques and meansEndodontic Topics, 2005
- Density of dentinal tubules affects the tensile strength of root dentinDental Materials, 2004
- Incomplete Crown‐Root Fracture in Pulpal‐Periodontal DiseaseJournal of Periodontology, 1973