Percutaneous closure of ventricular septal defect using LifeTechTM Konar-MF VSD Occluder: initial and short-term multi-institutional results
Authors:
- 28 July 2021
- journal article
- research article
- Published by Cambridge University Press (CUP) in Cardiology in the Young
- Vol. 32 (5) , 755-761
Abstract
Background: Transcatheter ventricular septal defect closure remains a complex procedure with potential complications like complete heart block and aortic regurgitation. The ideal device design for such intervention is still evolving.Aim: To assess the safety, efficacy, and short-term outcome of ventricular septal defect closure using LifeTechTM multifunctional (KONAR-MFTM) VSD Occluder.Patients and methods: In a multicenre study, 44 patients with haemodynamically significant, restrictive ventricular septal defects underwent closure with the KONAR-MFTM device from April, 2019 to March, 2020. Clinical, echocardiographic, and angiographic data were collected and reviewed. Patients were followed up at 1, 3, 6, and 12 months.Results: The median age and weight were 8 (1.7–36) years and 20 (11–79) kg. Of 44 patients, 8 (18%) had a high muscular and 36 (82%) had a perimembranous defect, of which 6 had mild prolapse of the right coronary cusp. The median ventricular septal defect size was 8.8 (3.9–13.4) mm. A retrograde approach was adopted in 39 (88.6%) patients. Nine patients (20.5%) had a small residual leak and there was a slight increase in aortic regurgitation in one patient. One device, which embolised to pulmonary artery was retrieved, and the defect was closed with a larger device. At a median follow-up of 13 (5–18) months, the residual leak persisted in 1 (2.3%) patient. Mild aortic regurgitation in one patient remained unchanged. There were no major complications.Conclusion: Percutaneous closure of ventricular septal defect using KONAR-MFTM device is safe and effective in short and midterm follow-up including selected patients with perimembranous defect and mild prolapse of the right coronary cusp.Keywords
This publication has 29 references indexed in Scilit:
- Use of Lifetech™ Konar-MF, a device for both perimembranous and muscular ventricular septal defects: A multicentre studyInternational Journal of Cardiology, 2020
- Percutaneous closure of restrictive‐type perimembranous ventricular septal defect using the new KONAR multifunctional occluder: Midterm outcomes of the first middle‐eastern experienceCatheterization and Cardiovascular Interventions, 2019
- First European experience of percutaneous closure of ventricular septal defects using a new CE-marked VSD occluderEuroIntervention, 2019
- Perimembranous Ventricular Septal Defect Device Closure: Choosing Between Amplatzer Duct Occluder I and IIPediatric Cardiology, 2017
- Transcatheter closure of perimembranous ventricular septal defect using amplatzer ductal occluderCatheterization and Cardiovascular Interventions, 2013
- Risk Factors and Outcomes of Post-Procedure Heart Blocks After Transcatheter Device Closure of Perimembranous Ventricular Septal DefectJACC: Cardiovascular Interventions, 2012
- Transcatheter closure of perimembranous and intracristal ventricular septal defects with the shsma occluderCatheterization and Cardiovascular Interventions, 2011
- Complete heart block associated with device closure of perimembranous ventricular septal defectsThe Journal of Thoracic and Cardiovascular Surgery, 2008
- Percutaneous Closure of Perimembranous Ventricular Septal Defects with the Eccentric Amplatzer Device: Multicenter Follow-up StudyPediatric Cardiology, 2005
- Percutaneous closure of perimembranous ventricular septal defects with the Amplatzer device: Technical and morphological considerationsCatheterization and Cardiovascular Interventions, 2004