Research on the Reasonable Width of the Waterproof Coal Pillar during the Mining of a Shallow Coal Seam Located Close to a Reservoir
Authors:
Open Access
- 1 January 2019
- journal article
- research article
- Published by Wiley in Advances in Civil Engineering
- Vol. 2019 (1)
Abstract
Retaining a waterproof coal pillar is the most effective water conservation method for coal seam mining close to a reservoir, and determining a reasonable width for the waterproof coal pillar has been a common problem among mining scholars for a considerably long time. In case of mining a 4−2 coal seam close to the Changjiagou Reservoir in the Zhangjiamao mine, the research methods of theoretical analysis, physical simulation using similar materials, and numerical simulation have been adopted to analyze the overburden strata mining failure features and the surface subsidence law. Additionally, the influences of the width of the coal pillar on the reservoir bank slope stability have been investigated. The results denote that a coal pillar can be divided into a mine‐pressure‐influenced zone, an effective waterproof zone, and a water‐level‐influenced zone with respect to water resistance. Furthermore, the width of the waterproof coal pillar was determined to be 107.41 m by theoretical analysis. The simulation test indicated that when the working face advanced close to the reservoir, the reservoir bank exhibited vertical downward as well as transverse abscission layer fractures and the divided topsoil slipped toward the reservoir. Subsequently, the judgment conditions required for determining the critical width of the waterproof coal pillar were proposed based on the requirements to prevent the reservoir bank slope from instability failure and the water gushing accident in goaf. The maximum width of the waterproof coal pillar when the top point on the slope surface experienced reverse horizontal displacement and several key points produced sharp vertical displacements or when the pore pressure in the coal seam roof and floor suddenly became 0 was considered to be the critical width. Furthermore, the critical width was determined to be 96 m via simulation analysis, verifying the rationality of the theoretical method. These results could provide a theoretical basis for determining the width of the waterproof coal pillar of the coal seam located close to a reservoir.Keywords
Funding Information
- National Natural Science Foundation of China (41702346, 11872299)
- Education Department of Shaanxi Province (17JK0502)
- Xi'an University of Science and Technology (201729)
This publication has 13 references indexed in Scilit:
- Failure Characteristics and Confined Permeability of an Inclined Coal Seam Floor in Fluid‐Solid CouplingAdvances in Civil Engineering, 2018
- Three Zones and Support Technique for Large Section Incline Shaft Crossing GoafGeotechnical and Geological Engineering, 2017
- Height of the mining-induced fractured zone above a coal faceEngineering Geology, 2017
- Deformation, failure and permeability of coal-bearing strata during longwall miningEngineering Geology, 2016
- A new approach for predicting bedding separation of roof strata in underground coalminesInternational Journal of Rock Mechanics and Mining Sciences, 2013
- Fractured zone height of longwall mining and its effects on the overburden aquifersInternational Journal of Mining Science and Technology, 2012
- In situ explorations on zonal disintegration of roof strata in deep coalminesInternational Journal of Rock Mechanics and Mining Sciences, 2012
- The height of fractured water-conducting zone in undermined rock strataEngineering Geology, 2011
- Impact of Coal Mining on Karst Water System in North ChinaProcedia Earth and Planetary Science, 2011
- Field trials of aquifer protection in longwall mining of shallow coal seams in ChinaInternational Journal of Rock Mechanics and Mining Sciences, 2010