Classification of Normal and Hypoxic Fetuses From Systems Modeling of Intrapartum Cardiotocography
Authors:
- 22 March 2010
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 57 (4) , 771-779
Abstract
Recording of maternal uterine pressure (UP) and fetal heart rate (FHR) during labor and delivery is a procedure referred to as cardiotocography. We modeled this signal pair as an input-output system using a system identification approach to estimate their dynamic relation in terms of an impulse response function. We also modeled FHR baseline with a linear fit and FHR variability unrelated to UP using the power spectral density, computed from an auto-regressive model. Using a perinatal database of normal and pathological cases, we trained suport-vector-machine classifiers with feature sets from these models. We used the classification in a detection process. We obtained the best results with a detector that combined the decisions of classifiers using both feature sets. It detected half of the pathological cases, with very few false positives (7.5%), 1 h and 40 min before delivery. This would leave sufficient time for an appropriate clinical response. These results clearly demonstrate the utility of our method for the early detection of cases needing clinical intervention.Keywords
This publication has 27 references indexed in Scilit:
- 631: Progression of intrapartum EFM patterns in births with symptomatic metabolic acidosisAmerican Journal of Obstetrics and Gynecology, 2007
- Linear models of intrapartum uterine pressure-fetal heart rate interaction for the normal and hypoxic fetus2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), 2006
- Comparison of Entropy-Based Regularity Estimators: Application to the Fetal Heart Rate Signal for the Identification of Fetal DistressIEEE Transactions on Biomedical Engineering, 2005
- Toward Quantitative Fetal Heart Rate MonitoringIEEE Transactions on Biomedical Engineering, 2005
- Quantifying Errors in Spectral Estimates of HRV Due to Beat Replacement and ResamplingIEEE Transactions on Biomedical Engineering, 2005
- Surrogate time seriesPhysica D: Nonlinear Phenomena, 2000
- 5 Intrapartum assessment of uterine activityBailliere's Clinical Obstetrics and Gynaecology, 1996
- Testing for nonlinearity in time series: the method of surrogate dataPhysica D: Nonlinear Phenomena, 1992
- Two-sided linear filter identificationMedical & Biological Engineering & Computing, 1983
- FIR digital filter design techniques using weighted Chebyshev approximationProceedings of the IEEE, 1975