Analytical validation of an in‐house method for adenosine deaminase determination
- 29 November 2018
- journal article
- research article
- Published by Wiley in Journal of Clinical Laboratory Analysis
- Vol. 33 (3) , e22823
Abstract
Background: The adenosine deaminase (ADA) enzyme is a marker of inflammatory processes whose activity can be measured through a colorimetric method developed as an in‐house assay. This validation can reduce costs and expand the alternatives for laboratory diagnosis.Methods: The ADA analysis was achieved through a modified form of Giusti and Galanti's (1984) method. The following parameters were characterized: calibration curve, linearity, analytical sensitivity, limit of detection, limit of quantification, method working range, precision (within‐assay and between‐assay), bias, total analytical error, and sample stability. The results were statistically evaluated and compared with quality specifications based on biological variations and the performance of commercial tests.Results: The analytical sensitivity and limit of detection (0.013 and 3.0 U/L, respectively) were lower than those of commercial tests. The method's working range was 3.2‐100.0 U/L. According to the quality specification, the method showed optimum performance with a bias <3.5%. However, repeatability (2.2% and 1.7% for normal‐ and high‐activity samples, respectively) and reproducibility achieved worse results when compared to commercial tests. The method demonstrated an inappropriate between‐assay precision for low enzymatic activity (10.4%) and the minimum and desirable performance for medium (8.8%) and high (5.0%) activities, respectively. It also presented at least a minimum performance (<25%) for the total analytical error of the three analyzed samples. The pleural fluid samples were found to be stable at −20°C for six days.Conclusion: The findings show that the in‐house method displays an acceptable performance and is capable of generating results comparable to existing commercial tests.Keywords
This publication has 13 references indexed in Scilit:
- Useful measures and models for analytical quality management in medical laboratoriesClinical Chemistry and Laboratory Medicine (CCLM), 2016
- Understanding Bland Altman analysisBiochemia Medica, 2015
- Diagnosis of tuberculosis pleurisy with adenosine deaminase (ADA): a systematic review and meta-analysis2014
- Adenosine Deaminase in the Modulation of Immune System and its Potential as a Novel Target for Treatment of Inflammatory DisordersCurrent Drug Targets, 2012
- Validation And Verification of Measurement Methods in Clinical ChemistryBioanalysis, 2012
- [Diagnostic tools in tuberculosis].2011
- Validação laboratorial de um método automatizado de dosagem da atividade de adenosina desaminase em líquido pleural e em líquido cefalorraquidianoJornal Brasileiro de Pneumologia, 2008
- Exame do líquido cefalorraquidiano: influência da temperatura, tempo e preparo da amostra na estabilidade analíticaJornal Brasileiro de Patologia e Medicina Laboratorial, 2008
- Avaliação da adenosina desaminase no diagnóstico da tuberculose pleural: uma metanálise brasileiraJornal Brasileiro de Pneumologia, 2008
- Dosagem da atividade da adenosina deaminase no líquido pleural para o diagnóstico da tuberculose pleuralJornal Brasileiro de Pneumologia, 2004