Objective: To evaluate the clinical applicability of a semiautomatic radiological tool for scalar translocation detection. Study Design: Retrospective study. Setting: Tertiary care academic center. Patients: We included 104 patients implanted with 116 HiFocus Mid-Scala electrode arrays between January 2013 and September 2016. Intervention: Cochlear implantation. Main Outcome Measures: The tool's scalar position assessments were compared with manual ones by calculating intraclass coefficient (ICC) for individual contacts and sensitivity and specificity for translocation detection of the whole array. In addition, ICC was calculated for diameters A and B, ratio A/B, and angular insertion depth (AID). Results: Nine-one percent of cases could be processed, which took 5 to 10 minutes per case. Comparison of manual and semiautomatic scalar position showed for individual contacts an ICC of 0.89 and for the whole array a sensitivity of 97% and a specificity of 96%. ICCs for A, B, and A/B were 0.82, 0.74, and 0.39 respectively. For AID, ICC of each of the 16 contacts was 0.95 or higher. Conclusions: The semiautomatic radiological tool could analyze most cases and showed good to excellent agreement with manual assessments for translocation detection, diameter A, diameter B, and AID. The variability between semiautomatic and manual measurements is comparable to interobserver variability, indicating that clinical implementation of the tool is feasible.Keywords
This publication has 26 references indexed in Scilit:
- Automatic electrode scalar location assessment after cochlear implantation using a novel imaging softwareScientific Reports, 2023
- Accuracy of radiological prediction of electrode position with otological planning software and implications of high-resolution imagingCochlear Implants International, 2023
- 3D-localisation of cochlear implant electrode contacts in relation to anatomical structures from in vivo cone-beam computed tomographyHearing Research, 2022
- Cochlear duct length and cochlear distance on preoperative CT: imaging markers for estimating insertion depth angle of cochlear implant electrodeEuropean Radiology, 2021
- Scalar Translocation Comparison Between Lateral Wall and Perimodiolar Cochlear Implant Arrays ‐ A Meta‐AnalysisThe Laryngoscope, 2020
- Cochlear ImplantOtolaryngologic Clinics of North America, 2020
- Review on cochlear implant electrode array tip fold-over and scalar deviationJournal of Otology, 2019
- Variations in cochlear duct shape revealed on clinical CT images with an automatic tracing methodScientific Reports, 2017
- Active Shape Models-Their Training and ApplicationComputer Vision and Image Understanding, 1995
- Guidelines, criteria, and rules of thumb for evaluating normed and standardized assessment instruments in psychology.Psychological Assessment, 1994