Electrical and Thermal Effects of Esophageal Temperature Probes on Radiofrequency Catheter Ablation of Atrial Fibrillation: Results from a Computational Modeling Study
- 27 March 2015
- journal article
- research article
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 26 (5) , 556-564
Abstract
Electrical and Thermal Effects of Esophageal Temperature Probes: Introduction: Luminal esophageal temperature (LET) monitoring is commonly employed during catheter ablation of atrial fibrillation (AF) to detect high esophageal temperatures during radiofrequency (RF) delivery along the posterior wall of the left atrium. However, it has been recently suggested that in some cases the esophageal probe itself may serve as an RF “antenna” and promote esophageal thermal injury. The aim of this study was to assess the electrical and thermal interferences induced by different types of commercially available esophageal temperature probes (ETPs) on RF ablation.Methods and Results: In this study, we developed a computational model to assess the electrical and thermal effects of 3 different types of ETPs: a standard single‐sensor and 2 multisensor probes (1 with and 1 without metallic surfaces). LET monitoring invariably underestimated the maximum temperature reached in the esophageal wall. RF energy cessation guided by LET monitoring using an ETP yielded lower esophageal wall temperatures. Also, the phenomenon of thermal latency was observed, particularly in the setting of LET monitoring. Most importantly, while only the ETP with a metallic surface produced minimal electrical alterations, the magnitude of this interference did not appear to be clinically significant.Conclusion: Temperature rises in both the esophageal wall and the ETP seem to be primarily produced by thermal conduction, and not caused by electrical and/or thermal interactions between the ablation catheter and the ETP, itself. As such, the proposed notion of the “antenna effect” producing satellite esophageal lesions during AF ablation was not evident in this study.Keywords
Funding Information
- Plan Nacional de I+D+i del Ministerio de Ciencia e Innovación (TEC2011-27133-C02-01)
This publication has 23 references indexed in Scilit:
- Multi‐Sensor Esophageal Temperature Probe Used During Radiofrequency Ablation for Atrial Fibrillation is Associated with Increased Intraluminal Temperature Detection and Increased Risk of Esophageal Injury Compared to Single‐Sensor ProbeJournal of Cardiovascular Electrophysiology, 2013
- Utility of Esophageal Temperature Monitoring During Pulmonary Vein Isolation for Atrial Fibrillation Using Duty-Cycled Phased Radiofrequency AblationJournal of Cardiovascular Electrophysiology, 2010
- A Theoretical and Experimental Analysis of Radiofrequency Ablation with a Multielectrode, Phased, Duty-Cycled SystemPacing and Clinical Electrophysiology, 2010
- Esophageal Injury and Temperature Monitoring During Atrial Fibrillation AblationCirculation: Arrhythmia and Electrophysiology, 2008
- Esophageal temperature monitoring during radiofrequency catheter ablation: experimental study based on an agar phantom modelPhysiological Measurement, 2007
- Esophageal Temperature During Radiofrequency-Catheter Ablation of Left Atrium: A Three-Dimensional Computer Modeling StudyJournal of Cardiovascular Electrophysiology, 2006
- Comparison of Electrode Cooling Between Internal and Open Irrigation in Radiofrequency Ablation Lesion Depth and Incidence of Thrombus and Steam PopCirculation, 2006
- What affects esophageal injury during radiofrequency ablation of the left atrium? An engineering study based on finite-element analysisPhysiological Measurement, 2005
- In Vivo Measurement of Swine Endocardial Convective Heat Transfer CoefficientIEEE Transactions on Biomedical Engineering, 2004
- Numerical model for radio-frequency ablation of the endocardium and its experimental validationIEEE Transactions on Biomedical Engineering, 1994