Toric intraocular lens implantation: 100 consecutive cases
Authors:
- Paul R. YoderPYPaul R. Yoder
- Thomas K. WilcoxTWThomas K. Wilcox
- Jeffrey L. SpielmanJSJeffrey L. Spielman
- 1 February 2002
- journal article
- clinical trial
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 28 (2) , 295-301
Abstract
To evaluate the first 100 consecutive cases of toric posterior chamber silicone intraocular lens (IOL) implantation by 2 community-based ophthalmologists. Two private practices in western Virginia, USA. Data on the first 100 consecutive toric IOL implantations in 81 patients were collected in a prospective manner. Cataract surgery was performed using topical anesthesia and phaco-chop, phaco-flip, or divide-and-conquer phacoemulsification. A Staar AA4203TF or AA4203TL IOL with a 2.00 diopter (D) or 3.50 D toric power was implanted using a lens injector. After the viscoelastic material was removed, the IOL was rotated to the desired orientation. The IOL orientation was assessed postoperatively at 1 day, 1 to 2 weeks, and the last visit. The mean follow-up was 23 weeks +/- 17 (SD). The IOLs performed in a predicable fashion. The mean astigmatism correction with IOLs within 15 degrees of the intended axis was 1.62 D with the 2.00 D IOL and 2.86 D with the 3.50 D IOL. Eleven patients had IOLs that were rotated more than 15 degrees away from the intended axes; in 3, the astigmatism was worse than preoperatively. The mean preoperative refractive and keratometric astigmatism was 2.48 D and 2.11 D, respectively. The mean postoperative astigmatism was 0.87 D and 2.05 D, respectively. At the last follow-up, half the patients had residual refractive astigmatism of 0.50 D or less and 45% had an uncorrected visual acuity of 20/30 or better. Of postoperative patients with a 20/30 visual acuity with or without correction, 52% could see this well no correction. The results show that toric IOL implantation can help an estimated 20% of patients with astigmatism achieve good vision and a reduced need for distance spectacles. If IOL rotation occurs, it is usually during the first week and can be remedied by repositioning the IOL at 1 week.Keywords
This publication has 6 references indexed in Scilit:
- Astigmatism correction with a foldable toric intraocular lens in cataract patientsJournal of Cataract & Refractive Surgery, 2000
- Implantation of a toric poly(methyl methacrylate) intraocular lens to correct high astigmatismJournal of Cataract & Refractive Surgery, 1999
- Decentration of 3-piece versus plate-haptic silicone intraocular lensesJournal of Cataract & Refractive Surgery, 1998
- Astigmatism and the toric intraocular lens and other vertex distance effectsSurvey of Ophthalmology, 1997
- Toric intraocular lenses: Correcting astigmatism while controlling axis shiftJournal of Cataract & Refractive Surgery, 1994
- Photorefractive Keratectomy to Create Toric Ablations for Correction of AstigmatismArchives of Ophthalmology (1950), 1991