Appropriate and Inappropriate Electrical Therapies Delivered by an Implantable Cardioverter-Defibrillator: Effect on Intracardiac Electrogram
- 18 November 2010
- journal article
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 22 (5) , 554-560
Abstract
Intracardiac EGM After ICD Therapies. Introduction: Local injury current (LIC) seen after induced ventricular fibrillation rescue implantable cardioverter‐defibrillator (ICD) shock predicts heart failure progression. We sought to determine the frequency of LIC after spontaneous events in patients receiving ICD therapies. Methods and Results: Near‐field (NF) right ventricular (RV) EGM during 10 seconds after delivered ICD therapy was compared with baseline EGM in 420 events that occurred in 134 patients (mean age 60.8 ± 14.8, 106 [79%] male). The magnitude of elevated or depressed potential immediately after the major fast EGM deflection was defined as LIC, and its ratio to the peak‐to‐peak EGM amplitude was defined as relative LIC. LIC of at least 1 mV or relative LIC of at least 15% was considered significant. LIC was observed in 121 events (28.8%) and was detected more frequently after appropriate (43 [60.6%] events) and inappropriate (56 [64.4%] events) ICD shocks, as compared with appropriate (8 [9.2%] events) and inappropriate (3 [4.7%] events) antitachycardia pacing (ATP) or nonsustained ventricular tachycardia (11 [9.9%] events) [ANOVA P < 0.0001]. Type of ICD therapy (ICD shock vs ATP) was the most significant predictor of LIC (ATP β coefficient −0.81; 95%CI–1.19 to 0.44); P < 0.0001), along with cycle length of tachycardia (β coefficient –0.0117; 95%CI –0.0167 to –0.0068, P < 0.00001) and shock energy (β coefficient 0.024; 95%CI 0.003–0.045, P = 0.025). Conclusion: Appropriate and inappropriate ICD shocks are frequently characterized by the development of LIC in patients with structural heart disease. Type of electrical ICD therapy, shock energy and cycle length of ventricular arrhythmia are important determinants of LIC. (J Cardiovasc Electrophysiol, Vol. 22, pp. 554‐560 May 2011)Keywords
This publication has 23 references indexed in Scilit:
- Implantable Cardioverter-Defibrillators in Patients Hospitalized for Heart Failure With Chronically Reduced Left Ventricular Ejection FractionAmerican Journal of Therapeutics, 2010
- Current of injury predicts adequate active lead fixation in permanent pacemaker/defibrillation leadsJACC, 2005
- Amiodarone or an Implantable Cardioverter–Defibrillator for Congestive Heart FailureNew England Journal of Medicine, 2005
- Long-Term Clinical Course of Patients After Termination of Ventricular Tachyarrhythmia by an Implanted DefibrillatorCirculation, 2004
- Prospective Randomized Multicenter Trial of Empirical Antitachycardia Pacing Versus Shocks for Spontaneous Rapid Ventricular Tachycardia in Patients With Implantable Cardioverter-DefibrillatorsCirculation, 2004
- Mitochondrial permeability transition pore opening during myocardial reperfusion—a target for cardioprotectionCardiovascular Research, 2004
- Implantable Cardioverter–DefibrillatorsNew England Journal of Medicine, 2003
- Prophylactic Implantation of a Defibrillator in Patients with Myocardial Infarction and Reduced Ejection FractionNew England Journal of Medicine, 2002
- The Role of Electroporation in DefibrillationCirculation Research, 2000
- Improved Survival with an Implanted Defibrillator in Patients with Coronary Disease at High Risk for Ventricular ArrhythmiaNew England Journal of Medicine, 1996