Retrosigmoidal placement of an active transcutaneous bone conduction implant: surgical and audiological perspectives in a multicentre study
Authors:
Open Access
- 1 February 2021
- journal article
- research article
- Published by Pacini Editore in Acta Otorhinolaryngologica Italica
- Vol. 41 (1) , 91-99
Abstract
Introduction. The retrosigmoidal (RS) placement of the Bonebridge system (BB) has been advocated for cases of unfavourable anatomical or clinical conditions which contraindicate transmastoid-presigmoidal positioning. However, these disadvantageous conditions, combined with the considerable dimensions of the implant, may represent a challenge, especially for surgeons with no skull base experience. Moreover, the literature reports only limited experience concerning RS implantation of the BB system. Methods. A multicentre, retrospective study was conducted to analyse the surgical and functional outcomes of a wide population of patients undergoing RS placement of the BB system by means of a surgical technique specifically developed to overcome the intraoperative issues related to this surgery. Twenty patients with conductive or mixed hearing loss and single sided deafness were submitted to RS implantation of the BB system. Results. Audiological assessment concerning the measurement of the functional and effective gain by pure-tone audiometry (28 dB HL and -12.25 dB HL, respectively) and speech audiometry (24.7 dB HL and -21 dB HL, respectively) was conducted. A high overall subjective improvement of quality of life was recorded with the Glasgow Benefit Inventory questionnaire. No major complications, such as device extrusions or other conditions requiring revision surgery, were reported during the follow-up period (median: 42 months). Conclusions. In our study, which has one of the largest cohort of patients reported in the literature, RS placement of the BB system was safe and effective. Our functional results showed comparable hearing outcomes with presigmoidal placement. The effective gain, rarely investigated in this field, may be the object of further research to improve our understanding of bone conduction mechanisms exploited by bone conduction hearing implants.Keywords
This publication has 26 references indexed in Scilit:
- Active Bone Conduction System: Outcomes with the Bonebridge Transcutaneous DeviceORL, 2015
- New developments in bone-conduction hearing implants: a reviewMedical Devices: Evidence and Research, 2015
- Indication criteria and outcomes with the Bonebridge transcutaneous bone-conduction implantThe Laryngoscope, 2014
- The Bone Conduction Implant—First Implantation, Surgical and Audiologic AspectsOtology & Neurotology, 2014
- Topographic bone thickness maps for Bonebridge implantationsEuropean Archives of Oto-Rhino-Laryngology, 2014
- Retrosigmoid implantation of an active bone conduction stimulator in a patient with chronic otitis mediaAuris Nasus Larynx, 2014
- First European Multicenter Results With a New Transcutaneous Bone Conduction Hearing Implant SystemOtology & Neurotology, 2013
- Transcutaneous bone-conduction hearing device: audiological and surgical aspects in a first series of patients with mixed hearing lossActa Oto-Laryngologica, 2013
- Measuring Patient Benefit from Otorhinolaryngological Surgery and TherapyAnnals of Otology, Rhinology & Laryngology, 1996
- Early Bone Conduction Hearing Aid DevicesJAMA Otolaryngology–Head & Neck Surgery, 1976