Removal of urea by electro-oxidation in a miniature dialysis device: a study in awake goats
- 1 November 2018
- journal article
- research article
- Published by American Physiological Society in American Journal of Physiology-Renal Physiology
- Vol. 315 (5) , F1385-F1397
Abstract
The key to success in developing a wearable dialysis device is a technique to safely and efficiently regenerate and reuse a small volume of dialysate in a closed-loop system. In a hemodialysis model in goats, we explored whether urea removal by electro-oxidation (EO) could be effectively and safely applied in vivo. A miniature dialysis device was built, containing 1 or 2 “EO units,” each with 10 graphite electrodes, with a cumulative electrode surface of 585 cm2per unit. The units also contained poly(styrene-divinylbenzene) sulfonate beads, FeOOH beads, and activated carbon for respective potassium, phosphate, and chlorine removal. Urea, potassium, and phosphate were infused to create “uremic” conditions. Urea removal was dependent on total electrode surface area [removal of 8 mmol/h (SD 1) and 16 mmol/h (SD 2) and clearance of 12 ml/min (SD 1) and 20 ml/min (SD 3) with 1 and 2 EO units, respectively] and plasma urea concentration but not on flow rate. Extrapolating urea removal with 2 EO units to 24 h would suffice to remove daily urea production, but for intermittent dialysis, additional units would be required. EO had practically no effects on potassium and phosphate removal or electrolyte balance. However, slight ammonium releasewas observed, and some chlorine release at higher dialysate flow rates. Minor effects on acid-base balance were observed, possibly partly due to infusion of chloride. Mild hemolysis occurred, which seemed related to urea infusion. In conclusion, clinically relevant urea removal was achieved in vivo by electro-oxidation. Efficacy and safety testing in a large-animal model with uremia is now indicated.Keywords
Funding Information
- Nierstichting (Dutch Kidney Foundation) (NT 12.05)
- European Commission (EC) (FP7-ICT-2009-4)
- European Commission Directorate-General for Research and Innovation (733169)
This publication has 38 references indexed in Scilit:
- Phosphate removal model: An observational study of low‐flux dialyzers in conventional hemodialysis therapyHemodialysis International, 2012
- Effects of Dietary Phosphate and Calcium Intake on Fibroblast Growth Factor-23Clinical Journal of the American Society of Nephrology, 2011
- Review: Understanding sorbent dialysis systemsNephrology, 2010
- A peritoneal-based automated wearable artificial kidneyClinical and Experimental Nephrology, 2008
- Electrolyte-free water clearance: a key to the diagnosis of hypernatremia in resolving acute renal failureClinical and Experimental Nephrology, 2008
- The Vicenza Wearable Artificial Kidney for Peritoneal Dialysis (ViWAK PD)Blood Purification, 2007
- Continuous Renal Replacement Therapy for End-Stage Renal Disease2005
- How To Catch Urea? Considerations on Urea Removal from HemofiltrateArtificial Organs, 1981
- Intravascular Hemolysis Following Urea Administration During HypothermiaAnesthesiology, 1964