Abstract
To analyze the optic surface roughness and morphology of 2 types of hydrophobic acrylic intraocular lenses (IOLs) with various dioptric powers using atomic force microscopy (AFM). Technical University of Cluj-Napoca, Faculty of Mechanics, Cluj-Napoca, Romania. Atomic force microscopy was used to characterize the topography of 2 types of hydrophobic acrylic IOLs from a single manufacturer (SN60AT and SA30AL) with dioptric powers ranging from 10.0 diopters (D) to 30.0 D. The AFM analysis was performed in contact mode using a V-shaped silicon nitride cantilever with a pyramidal tip curvature of 15 nm and a nominal spring constant of 0.2 N/m. Detailed surface characterization of the IOL optic was obtained using 6 quantitative parameters provided by the AFM software. Five of 6 roughness parameters indicated statistically significant differences (P<.05) between IOLs with different dioptric powers, with the 10.0 D IOL in both models providing the smoothest optic surface. Between models with the same dioptric power, the SN60AT model had lower values of each surface roughness parameter than the SA30AL model. Atomic force microscopy was an accurate tool for assessing the surface properties of IOL optics. Manufacturing processes were responsible for introducing detectable differences in the topography of IOL biomaterials with identical copolymer constituents but different dioptric powers. Nanometric analysis may assist IOL manufacturers in developing IOLs with optimal surface characteristics.Keywords
This publication has 34 references indexed in Scilit:
- Effect of AcrySof versus Silicone or Polymethyl Methacrylate Intraocular Lens on Posterior Capsule OpacificationOphthalmology, 2008
- Cell adhesion to acrylic intraocular lens associated with lens surface propertiesJournal of Cataract & Refractive Surgery, 2005
- Long-term effect of optic edge design in an acrylic intraocular lens on posterior capsule opacificationJournal of Cataract & Refractive Surgery, 2005
- Effect of optic material on posterior capsule opacification in intraocular lenses with sharp-edge opticsRandomized clinical trialOphthalmology, 2005
- Effect of intraocular lenses on preventing posterior capsule opacificationJournal of Cataract & Refractive Surgery, 2004
- Relationship between posterior capsule opacification and intraocular lens biocompatibilityProgress in Retinal and Eye Research, 2004
- Posterior capsule opacification: Comparison of 3 intraocular lenses of different materials and designJournal of Cataract & Refractive Surgery, 2003
- Inhibition of lens epithelial cell migration at the intraocular lens optic edgeJournal of Cataract & Refractive Surgery, 2003
- Quantification of posterior capsule opacification with round and sharp edge intraocular lensesOphthalmology, 2003
- Relationship between intraocular lens biomaterials and posterior capsule opacificationJournal of Cataract & Refractive Surgery, 1998