Effects of anodal vs. cathodal pacing on the mechanical performance of the isolated rabbit heart
- 1 September 2000
- journal article
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 89 (3) , 1159-1164
Abstract
Previous studies have suggested that anodal pacing enhances electrical conduction in the heart near the pacing site. It was hypothesized that enhanced conduction by anodal pacing would also enhance ventricular pressure in the heart. Left ventricular pressure measurements were made in isolated, Langendorff-perfused rabbit hearts by means of a Millar pressure transducer with the use of a balloon catheter fixed in the left ventricle. The pressure wave was analyzed for maximum pressure (Pmax) generated in the left ventricle and the work done by the left ventricle (Parea). Eight hearts were paced with monophasic square-wave pulses of varying amplitudes (2, 4, 6, and 8 V) with 100 pulses of each waveform delivered to the epicardium. Anodal stimulation pulses showed statistically significant improvement in mechanical response at 2, 4, and 8 V. Relative to unipolar cathodal pacing, unipolar anodal pacing improved Pmax by 4.4 ± 2.3 (SD), 5.3 ± 3.1, 3.5 ± 4.9, and 4.8 ± 1.9% at 2, 4, 6, and 8 V, respectively. Unipolar anodal stimulation also improved Parea by 9.0 ± 3.0, 12.0 ± 6.0, 10.1 ± 7.7, and 11.9 ± 6.0% at 2, 4, 6, and 8 V, respectively. Improvements in Pmax and Parea indicate that an anodally paced heart has a stronger mechanical response than does a cathodally paced heart. Anodal pacing might be useful as a novel therapeutic technology to treat mechanically impaired or failed hearts.Keywords
This publication has 11 references indexed in Scilit:
- Mechanism of Anode Break Stimulation in the HeartBiophysical Journal, 1998
- Effect of varying pacing waveform shapes on propagation and hemodynamics in the rabbit heartThe American Journal of Cardiology, 1997
- Transmembrane Voltage Changes During Unipolar Stimulation of Rabbit VentricleCirculation Research, 1995
- Results and efficiency of programmed ventricular stimulation with four extrastimuli compared with one, two, and three extrastimuli.Circulation, 1994
- Virtual electrode effects in myocardial fibersBiophysical Journal, 1994
- Comparison of cathodal, anodal, and bipolar strength-interval curves with temporary and permanent pacing electrodes.Heart, 1979
- Vulnerability of the mildly ischemic ventricle to cathodal, anodal, and bipolar stimulation.Circulation Research, 1977
- Anodal stimulation as a cause of pacemaker-induced ventricular fibrillationAmerican Heart Journal, 1973
- Direct Current Make and Break Thresholds for Pacemaker Electrodes on the Canine VentricleCirculation Research, 1970
- Anodal Excitation of Cardiac MuscleAmerican Journal of Physiology-Legacy Content, 1957