Suspect screening and target quantification of multi-class pharmaceuticals in surface water based on large-volume injection liquid chromatography and time-of-flight mass spectrometry
- 16 March 2014
- journal article
- research article
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 406 (11) , 2533-2547
Abstract
The ever-growing number of emerging micropollutants such as pharmaceuticals requests rapid and sensitive full-spectrum analytical techniques. Time-of-flight high-resolution mass spectrometry (TOF-HRMS) is a promising alternative for the state-of-the-art tandem mass spectrometry instruments because of its ability to simultaneously screen for a virtually unlimited number of suspect analytes and to perform target quantification. The challenge for such suspect screening is to develop a strategy, which minimizes the false-negative rate without restraining numerous false-positives. At the same time, omitting laborious sample enrichment through large-volume injection ultra-performance liquid chromatography (LVI-UPLC) avoids selective preconcentration. A suspect screening strategy was developed using LVI-UPLC-TOF-MS aiming the detection of 69 multi-class pharmaceuticals in surface water without the a priori availability of analytical standards. As a novel approach, the screening takes into account the signal-intensity-dependent accurate mass error of TOF-MS, hereby restraining 95 % of the measured suspect pharmaceuticals present in surface water. Application on five Belgian river water samples showed the potential of the suspect screening approach, as exemplified by a false-positive rate not higher than 15 % and given that 30 out of 37 restrained suspect compounds were confirmed by the retention time of analytical standards. Subsequently, this paper discusses the validation and applicability of the LVI-UPLC full-spectrum HRMS method for target quantification of the 69 pharmaceuticals in surface water. Analysis of five Belgian river water samples revealed the occurrence of 17 pharmaceuticals in a concentration range of 17 ng L−1 up to 3.1 μg L−1.Keywords
This publication has 46 references indexed in Scilit:
- Multiresidue analytical method for the simultaneous determination of 72 micropollutants in aqueous samples with ultra high performance liquid chromatography–high resolution mass spectrometryJournal of Chromatography A, 2012
- Simultaneous measurement in mass and mass/mass mode for accurate qualitative and quantitative screening analysis of pharmaceuticals in river waterJournal of Chromatography A, 2012
- Occurrence, fate and determination of cytostatic pharmaceuticals in the environmentTrAC Trends in Analytical Chemistry, 2011
- Water Analysis: Emerging Contaminants and Current IssuesAnalytical Chemistry, 2011
- Building an empirical mass spectra library for screening of organic pollutants by ultra‐high‐pressure liquid chromatography/hybrid quadrupole time‐of‐flight mass spectrometryRapid Communications in Mass Spectrometry, 2010
- Source, occurrence and fate of antibiotics in the Italian aquatic environmentJournal of Hazardous Materials, 2010
- Determination of four fluoroquinolone antibiotics in tap water in Guangzhou and MacaoEnvironmental Pollution, 2010
- Determination of 19 sulfonamides in environmental water samples by automated on-line solid-phase extraction-liquid chromatography–tandem mass spectrometry (SPE-LC–MS/MS)Talanta, 2010
- EU-wide survey of polar organic persistent pollutants in European river watersEnvironmental Pollution, 2009
- Investigations into the accuracy and precision obtainable on accurate mass measurements on a quadrupole orthogonal acceleration time‐of‐flight mass spectrometer using liquid chromatography as sample introductionRapid Communications in Mass Spectrometry, 2003