Beam Tests of SNSPDs with 120 GeV Protons

Authors:
  • SLSangbaek Lee
    Sangbaek Lee
  • TPTomas Polakovic
    Tomas Polakovic
  • WAWhitney Armstrong
    Whitney Armstrong
  • ADAlan Dibos
    Alan Dibos
  • TDTimothy Draher
    Timothy Draher
  • NPNathaniel Pastika
    Nathaniel Pastika
  • ZMZein-Eddine Meziani
    Zein-Eddine Meziani
  • VNValentine Novosad
    Valentine Novosad

Abstract
We report the test results for a 120 GeV proton beam incident on superconducting nanowire particle detectors of various wire sizes. NbN devices with the same sensitive area were fabricated with different wire widths and tested at a temperature of 2.8 K. The relative detection efficiency was extracted from bias current scans for each device. The results show that the wire width is a critical factor in determining the detection efficiency and larger wire widths than 400 nm leads to inefficiencies at low bias currents. These results are particularly relevant for novel applications at accelerator facilities, such as the Electron-Ion Collider, where cryogenic cooling is readily available.