Optimization of an HPLC-HG-AFS method for screening Sb(v), Sb(iii), and Me3SbBr2in water samples
- 31 July 2002
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 17 (10) , 1400-1404
Abstract
A procedure for the separation and determination of inorganic and organic species of antimony based on the use of coupled high-performance liquid chromatography (HPLC) hydride generation (HG) atomic fluorescence spectrometry (AFS) is described. Me3SbBr2 and inorganic Sb(V) and Sb(III) were separated on an anion-exchange column [Hamilton PRPX-100 (100 × 4.1 mm)] using the concentration gradient between potassium hydroxide, 20 mM pH 11, and ammonium tartrate, 200 mM pH 5. The flow rate through the column was 1.5 mL min−1. The retention times were 0.98, 1.71 and 5.03 min for Me3SbBr2, Sb(V) and Sb(III), respectively. The hydrides were generated on-line with 3% m/v NaBH4 and 2 mol l−1 HNO3 solutions. The intensity of emission was linearly related to the concentration of the derivatized Me3SbBr2 species in the range 1.0–50.0 µg l−1 (r = 0.9996), Sb(V) species in the range 1.0–50.0 µg l−1 (r = 0.9998) and Sb(III) in the range 2.5–50.0 µg l−1 (r = 0.9998), with detection limits of 0.04 µg l−1 for Me3SbBr2, 0.09 µg l−1 for Sb(V) and 0.26 µg l−1 for Sb(III). The precisions evaluated using the relative standard deviation (RSD) were 6.8%, 2.4% and 3.3% for Me3SbBr2, Sb(V) and Sb(III), respectively. The method has a sensitivity suitable for monitoring drinking and surface waters according to the regulations established by the EU directives for antimony (10 ug 1−1), and it was applied to the speciation of inorganic and organic antimony in several spiked water samples. The precisions for well water, Merck and mineral water were limited in relation to Me3SbBr2 due to its conversion to Sb(V).Keywords
This publication has 13 references indexed in Scilit:
- Hydride generation atomic fluorescence spectrometry (HG-AFS) as a sensitive detector for Sb(iii) and Sb(v) speciation in waterJournal of Analytical Atomic Spectrometry, 2000
- The production of methylated organoantimony compounds byScopulariopsis brevicaulisApplied Organometallic Chemistry, 1998
- Determination of arsenic, antimony, selenium, tellurium and bismuth in nickel metal by hydride generation atomic fluorescence spectrometryAnalytica Chimica Acta, 1998
- Antimony biomethylation by mixed cultures of micro-organisms under anaerobic conditionsApplied Organometallic Chemistry, 1998
- Analytical methods for antimony speciation in waters at trace and ultratrace levels. A reviewAnalytical and Bioanalytical Chemistry, 1998
- Confirmation of the Biomethylation of Antimony CompoundsApplied Organometallic Chemistry, 1997
- Development of a Multi-element Hydride Generation–Inductively Coupled Plasma Mass Spectrometry Procedure for the Simultaneous Determination of Arsenic, Antimony and Selenium in WatersJournal of Analytical Atomic Spectrometry, 1997
- Methylated antimony(V) compounds: Synthesis, hydride generation properties and implications for aquatic speciationApplied Organometallic Chemistry, 1992
- Applicability of anodic-stripping voltammetry and graphite furnace atomic-absorption spectrometry to the determination of antimony in biological matrices: a comparative studyThe Analyst, 1985
- Direct volatilization-spectral emission type detection system for nanogram amounts of arsenic and antimonyAnalytical Chemistry, 1972