A capacitive biosensor for detection of staphylococcal enterotoxin B
- 19 December 2008
- journal article
- research article
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 393 (5) , 1539-1544
Abstract
A sensitive method for the detection of staphylococcal enterotoxin B (SEB) using a flow-injection capacitive biosensor is presented. SEB was purified from a crude culture filtrate of Staphylococcus aureus through three chromatographic steps. The first two steps were based on ion-exchange chromatography, and the last step was carried out on a gel filtration column. The SEB recovery values after the purification stages were 88%, 74%, and 12%, respectively. A horseradish peroxidase labeled antistaphylococcal enterotoxin B was prepared by the periodate method and was further employed in a sandwich-enzyme-linked immunosorbent assay (ELISA) for the determination of SEB concentrations in different samples obtained during the processing of the crude filtrate. The capacitive biosensor could detect SEB concentrations as low as 0.3 pg ml−1 with a linearity ranging from 2.8 pg ml−1 to 2.8 ng ml−1 under optimized conditions. The response time was about 10 min. A good agreement was achieved between the developed capacitive biosensor system and ELISA as a reference method for detection of SEB levels in different purification samples. The newly developed sensor has the benefits of simplicity, high sensitivity, and multiple use capability.Keywords
This publication has 41 references indexed in Scilit:
- Detection and Confirmation of Staphylococcal Enterotoxin B in Apple Juice and Milk Using Piezoelectric-Excited Millimeter-Sized Cantilever Sensors at 2.5 fg/mLAnalytical Chemistry, 2007
- Detection, Confirmation, and Quantification of Staphylococcal Enterotoxin B in Food Matrixes Using Liquid Chromatography−Mass SpectrometryAnalytical Chemistry, 2006
- The integration of gold nanoparticles with semi-conductive oligomer layer for development of capacitive immunosensorSensors and Actuators B: Chemical, 2005
- The evolving field of biodefence: therapeutic developments and diagnosticsNature Reviews Drug Discovery, 2005
- COMPARISON OF REVERSE PASSIVE LATEX AGGLUTINATION TEST AND IMMUNOBLOTTING FOR DETECTION OF STAPHYLOCOCCAL ENTEROTOXIN A AND BJournal of Food Safety, 2004
- A rapid and sensitive magnetic bead-based immunoassay for the detection of staphylococcal enterotoxin B for high-through put screeningMolecular and Cellular Probes, 2004
- Capacitive immunosensor for transferrin based on an o-aminobenzenthiol oligomer layerAnalytica Chimica Acta, 2002
- Development of a tetramethylrhodamine-labeled probe for a capillary electrophoresis-based competitive immunoassay of staphylococcal enterotoxin BAnalytica Chimica Acta, 2002
- Peer Reviewed: Biological Warfare DetectionAnalytical Chemistry, 2000
- Highly sensitive fluorogenic enzyme-linked immunosorbent assay: detection of staphylococcal enterotoxin BJournal of Microbiological Methods, 1994