Range uncertainty reductions in proton therapy may lead to the feasibility of novel beam arrangements which improve organ‐at‐risk sparing
Authors:
Open Access
- 15 May 2022
- journal article
- research article
- Published by Wiley in Medical Physics
- Vol. 49 (7) , 4693-4704
Abstract
Purpose: In proton therapy, dose distributions are currently often conformed to organs at risk (OARs) using the less sharp dose fall‐off at the lateral beam edge to reduce the effects of uncertainties in the in vivo proton range. However, range uncertainty reductions may make greater use of the sharper dose fall‐off at the distal beam edge feasible, potentially improving OAR sparing. We quantified the benefits of such novel beam arrangements.Methods: For each of 10 brain or skull base cases, five treatment plans robust to 2 mm setup and 0%–4% range uncertainty were created for the traditional clinical beam arrangement and a novel beam arrangement making greater use of the distal beam edge to conform the dose distribution to the brainstem. Metrics including the brainstem normal tissue complication probability (NTCP) with the endpoint of necrosis were determined for all plans and all setup and range uncertainty scenarios.Results: For the traditional beam arrangement, reducing the range uncertainty from the current level of approximately 4% to a potentially achievable level of 1% reduced the brainstem NTCP by up to 0.9 percentage points in the nominal and up to 1.5 percentage points in the worst‐case scenario. Switching to the novel beam arrangement at 1% range uncertainty improved these values by a factor of 2, that is, to 1.8 percentage points and 3.2 percentage points, respectively. The novel beam arrangement achieved a lower brainstem NTCP in all cases starting at a range uncertainty of 2%.Conclusion: The benefits of novel beam arrangements may be of the same magnitude or even exceed the direct benefits of range uncertainty reductions. Indirect effects may therefore contribute markedly to the benefits of reducing proton range uncertainties.Keywords
This publication has 56 references indexed in Scilit:
- PTV-based IMPT optimization incorporating planning risk volumes vs robust optimizationMedical Physics, 2013
- Treatment planning optimisation in proton therapyBritish Journal of Radiology, 2013
- TOPAS: An innovative proton Monte Carlo platform for research and clinical applicationsMedical Physics, 2012
- Influence of robust optimization in intensity‐modulated proton therapy with different dose delivery techniquesMedical Physics, 2012
- Range uncertainties in proton therapy and the role of Monte Carlo simulationsPhysics in Medicine & Biology, 2012
- Robust optimization of intensity modulated proton therapyMedical Physics, 2012
- Minimax optimization for handling range and setup uncertainties in proton therapyMedical Physics, 2011
- Radiation Associated Brainstem InjuryInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2010
- Patient Study of In Vivo Verification of Beam Delivery and Range, Using Positron Emission Tomography and Computed Tomography Imaging After Proton TherapyInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2007
- A pencil beam algorithm for proton dose calculationsPhysics in Medicine & Biology, 1996