Efficient Oxidase Biosensors Based on Bioelectrocatalytic Surfaces of Electrodeposited Ferrocenyl Polycyclosiloxanes—Pt Nanoparticles
Open Access
- 15 April 2021
- journal article
- research article
- Published by MDPI AG in Chemosensors
- Vol. 9 (4) , 81
Abstract
The in-situ synthesis of catalytic surfaces with metallic nanoparticles must overcome the issues related to particle aggregation and polydispersity in the particle size. This work achieves it by using two electrodeposited ferrocenyl polycyclosiloxane polymers (MFPP and FPP) as templates for electro-synthesize Pt nanoparticles (PtNPS). In addition, this new electrode surface combines two efficient electrocatalysts: Ferrocene and Pt nanoparticles, with synergistic biocatalytic properties that constitute an electrocatalytic framework for the covalent immobilization of xanthine oxidase. In this work, we present the results of the kinetic, electrochemical and analytical studies of the prepared electrodes. These results showed that the PtNPs/FPP system is the best bioelectrocatalytic surface and improves other more complex xanthine oxidase devices based on the hydrogen peroxide oxidation, allowing the use of lower measuring potential with good sensitivity, wider linear ranges and low detection limits. In addition, this electrode provides the novelty of allowing the measurement of xanthine through the enzymatic consumption of oxygen at potential −0.1 V with a sensitivity of 1.10 A M−1 cm−2, linear ranges of 0.01–0.1 and 0.1–1.4 mM, low detection limit (48 nM) and long-term stability. The new device has been successfully applied to the determination of xanthine in fish meat.Keywords
Funding Information
- Dirección General de Proyectos de Investigación del Ministerio de Ciencia e Innovación (CTQ-2009-12321-C02)
This publication has 38 references indexed in Scilit:
- Design of an amperometric xanthine biosensor based on a graphite transducer patterned with noble metal microparticlesOpen Chemistry, 2010
- Sensitive and selective xanthine amperometric sensors based on calcium carbonate nanoparticlesSensors and Actuators B: Chemical, 2009
- Electrocatalytical properties of polymethylferrocenyl dendrimers and their applications in biosensingBioelectrochemistry, 2006
- Ferrocenyl and permethylferrocenyl cyclic and polyhedral siloxane polymers as mediators in amperometric biosensorsJournal of Organometallic Chemistry, 2004
- Amperometric enzyme electrodes for aerobic and anaerobic glucose monitoring prepared by glucose oxidase immobilized in mixed ferrocene–cobaltocenium dendrimersBiosensors and Bioelectronics, 2004
- Probing Biomolecular Interactions at Conductive and Semiconductive Surfaces by Impedance Spectroscopy: Routes to Impedimetric Immunosensors, DNA‐Sensors, and Enzyme BiosensorsElectroanalysis, 2003
- Effect of pH on the catalytic electrooxidation of NADH using different two-electron mediators immobilised on zirconium phosphateJournal of Electroanalytical Chemistry, 2001
- Evaluation of beef aging by determination of hypoxanthine and xanthine contents: application of a xanthine sensorFood Chemistry, 1995
- Synthesis of the First Redox-Active Organometallic Polymers Containing Cyclosiloxanes as FrameworksOrganometallics, 1995
- Polymeric redox mediator enzyme electrodes for anaerobic glucose monitoringJournal of Electroanalytical Chemistry, 1993