Investigating a possible cause of mesh migration during totally extraperitoneal (TEP) repair

Authors:

Abstract
In experienced hands, laparoscopic inguinal hernia repair has a low rate of recurrence, but it still can recur, and a number of reasons for this have been identified. In published studies, the majority of such cases seem to result from inadequate dissection leading to missed hernias or suboptimal mesh placement. But even with adequate dissection and proper placement of a sufficiently large mesh, recurrence sometimes happens. A number of investigators have cited mesh migration or dislocation as a possible cause, and this study examined how hip flexion affects the position of newly placed meshes and staples in totally extraperitoneal (TEP) repair of inguinal hernia.

This publication has 14 references indexed in Scilit: