Mini-haptics to improve capsular fixation of plate-haptic silicone intraocular lenses
Authors:
- Qun PengQPQun Peng
- Robert T. IsaacsRIRobert T. Isaacs
- Stephen B. WhitesideSWStephen B. Whiteside
- Derek L. BarkerDBDerek L. Barker
- David J. AppleDADavid J. Apple
- 1 May 1998
- journal article
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 24 (5) , 666-671
Abstract
To evaluate the effects of a new mini-haptic design on the strength and stability of capsular bag fixation of plate-haptic silicone intraocular lenses (IOLs) and determine whether this design encourages the growth of regenerating lens material or fibrous tissue around the haptic biomaterial and thus improves lens fixation in the capsular bag. Center for Research on Ocular Therapeutics and Biodevices, Storm Eye Institute, Medical University of South Carolina, Department of Ophthalmology, Charleston, South Carolina, USA. Six rabbits had bilateral continuous curvilinear capsulorhexis, phacoemulsification, and plate-haptic silicone IOL implantation. Each rabbit had a small-hole plate IOL (Chiron C10UB) implanted in the right eye and a mini-haptic plate IOL (Chiron C40UB) in the left eye. All rabbits were killed at 2 months. The force required to extract one haptic from the capsular bag was measured with a digital force gauge. Histopathologic analysis was performed on all specimens. The mini-haptic style IOLs required significantly more extraction force than the small-hole design (P = .011). Histopathologically, proliferating lens epithelial cells were observed growing circumferentially around the mini-haptics, causing a 360 degree synechia formation. This formation did not occur with the conventional small-hole plate IOLs used as the control. Lens epithelial cell proliferation around the mini-haptics significantly improved capsular bag fixation of the plate-haptic silicone IOL. This should decrease the incidence of clinical decentration and dislocation.Keywords
This publication has 7 references indexed in Scilit:
- Decentration of Plate-Haptic LensesJournal of Cataract & Refractive Surgery, 1996
- Clinical results of implanting a silicone haptic-anchor-plate intraocular lensJournal of Cataract & Refractive Surgery, 1996
- Centration and fixation of silicone intraocular lenses: Clinicopathological findings in human autopsy eyesJournal of Cataract & Refractive Surgery, 1996
- Analysis of 100 Explanted One-piece and Three-piece Silicone Intraocular LensesOphthalmology, 1995
- Pathology of silicone intraocular lenses in human eyes obtained postmortemJournal of Cataract & Refractive Surgery, 1995
- Postoperative complications and uncorrected acuities after implantation of plate haptic silicone and three-piece silicone intraocular lensesJournal of Cataract & Refractive Surgery, 1993
- Preparation and Study of Human Eyes Obtained Postmortem with the Miyake Posterior Photographic TechniqueOphthalmology, 1990