In this study, it is demonstrated that fat saturation (FS) preparation (prep) pulses generate incidental magnetization transfer contrast (MTC) in multislice Look‐Locker (LL) imaging. It is shown that frequency‐selective FS prep pulses can invoke MTC through the exchange between free and motion‐restricted protons. Simulation reveals that the fractional signal loss by these MTC effects is more severe for smaller flip angles (FAs), shorter repetition times (TRs), and greater number of slices (SN). These incidental MTC effects result in a signal attenuation at a steady state (up to 30%) and a T 1 measurement bias (up to 20%) when using inversion recovery (IR) LL echo‐planar imaging (EPI) sequences. Furthermore, it is shown that water‐selective MRI using binomial pulses has the potential to minimize the signal attenuation and provide unbiased T 1 measurement without fat artifacts in MR images. Magn Reson Med, 2009.Keywords
This publication has 21 references indexed in Scilit:
- Fast high‐resolution T1 mapping using inversion‐recovery look‐locker echo‐planar imaging at steady state: Optimization for accuracy and reliabilityMagnetic Resonance in Medicine, 2009
- Systematic Variation of Off-Resonance Prepulses for Clinical Magnetization Transfer Contrast Imaging at 0.2, 1.5, and 3.0 TeslaInvestigative Radiology, 2008
- On the origin of apparent low tissue signals in balanced SSFPMagnetic Resonance in Medicine, 2006
- Pulsed magnetization transfer imaging with body coil transmission at 3 Tesla: Feasibility and applicationMagnetic Resonance in Medicine, 2006
- Factors influencing flip angle mapping in MRI: RF pulse shape, slice‐select gradients, off‐resonance excitation, and B0 inhomogeneitiesMagnetic Resonance in Medicine, 2006
- Quantitative CBV measurement from static T1 changes in tissue and correction for intravascular water exchangeMagnetic Resonance in Medicine, 2006
- Pulsed magnetization transfer spin‐echo MR imagingJournal of Magnetic Resonance Imaging, 1993
- Magnetization transfer effects in multislice RARE sequencesMagnetic Resonance in Medicine, 1992
- Magnetization transfer contrast (MTC) and tissue water proton relaxation in vivoMagnetic Resonance in Medicine, 1989
- A comparison of one‐shot and recovery methods in T1 imagingMagnetic Resonance in Medicine, 1988