Accurate measurement of mitral annular area by using single and biplane linear measurements: comparison of conventional methods with the three-dimensional planimetric method
Authors:
Open Access
- 30 December 2011
- journal article
- research article
- Published by Oxford University Press (OUP) in European Heart Journal - Cardiovascular Imaging
- Vol. 13 (7) , 605-611
Abstract
The planimetry method using three-dimensional (3D) echocardiography is useful for providing an accurate mitral annulus area (MAA) value. However, this method is relatively unavailable. Therefore, we evaluated the accuracy of conventional methods for MAA measurement compared with that of 3D planimetry. Two-dimensional (2D) and 3D transoesophageal echocardiography (TEE) were performed in 70 patients. The mitral annulus diameter (MAD) was measured using four standard TEE imaging planes: four-chamber (4Ch), two-chamber (2Ch), anterior–posterior (LAX), and commissure–commissure (CC). MAA was calculated using a single diameter based on that of a circle and using two diameters based on that of an ellipse. MAA measurements using the single 4Ch MAD method (r = 0.84, P < 0.001), and two anatomically orthogonal MAD method in 4Ch/2Ch (r = 0.93, P < 0.001) and LAX/CC (r = 0.97, P < 0.001) planes correlated with 3D planimetric MAA measurements. Further analysis with Bland–Altman plots revealed that the LAX/CC MAD measurement exhibited the closest limits of agreement with the 3D planimetric MAA measurement. Notably, in patients showing an elliptical annulus shape, only LAX/CC MAD, but not 4Ch or 4Ch/2Ch MAD, provided results comparable with those of 3D planimetric MAA measurements. However, in patients with a circular annulus shape, reliable MAA measurements can be achieved using either single 4Ch MAD or any biplane MAD. Conventional LAX/CC MAD can be recommended for MAA measurements in a diverse patient population. This method is applicable as an alternative to the 3D planimetric method, regardless of the mitral annulus shape.Keywords
This publication has 22 references indexed in Scilit:
- Characterization of Degenerative Mitral Valve Disease Using Morphologic Analysis of Real-Time Three-Dimensional Echocardiographic ImagesCirculation: Cardiovascular Imaging, 2011
- Quantitative Mitral Valve Modeling Using Real-Time Three-Dimensional Echocardiography: Technique and RepeatabilityThe Annals of Thoracic Surgery, 2011
- RT-3D TEE: Characteristics of Mitral Annulus Using Mitral Valve Quantification (MVQ) ProgramEchocardiography, 2010
- Mitral Annular Dynamics in Myxomatous Valve DiseaseCirculation, 2010
- Long-term outcome of patients with heart failure and dynamic functional mitral regurgitationEuropean Heart Journal, 2005
- Quantitative Determinants of the Outcome of Asymptomatic Mitral RegurgitationNew England Journal of Medicine, 2005
- Experimental and clinical assessment of mitral annular area and dynamics: what are we actually measuring?The Annals of Thoracic Surgery, 2001
- Three-dimensional echocardiographic assessment of annular shape changes in the normal and regurgitant mitral valveAmerican Heart Journal, 2000
- Transoesophageal Doppler echocardiographic measurement of cardiac output by the mitral annulus methodHeart, 1992
- Pulsed Doppler echocardiographic determination of stroke volume and cardiac output: clinical validation of two new methods using the apical window.Circulation, 1984