Compressed Sensing‐Accelerated Free‐Breathing Liver MRI at 7 T
Authors:
- Mitra TavakkoliMTMitra Tavakkoli
- Bobby A. RunderkampBRBobby A. Runderkamp
- Matthijs H. S. de BuckMBMatthijs H. S. de Buck
- Gustav J. StrijkersGSGustav J. Strijkers
- Michael D. NoseworthyMNMichael D. Noseworthy
- Aart J. NederveenANAart J. Nederveen
- Matthan W. A. CaanMCMatthan W. A. Caan
- Wietske van der ZwaagWZWietske van der Zwaag
Open Access
- 28 April 2025
- journal article
- Published by Wiley in NMR in Biomedicine
- Vol. 38 (6) , e70047
Abstract
Ultra‐high field MRI facilitates imaging at high spatial resolutions, which may become important for detailed anatomical and pathological assessment of the human liver. Therefore, we aimed to advance structural liver imaging at 7 T by implementing a high‐resolution, phase‐shimmed, free‐breathing liver scan. Six healthy participants underwent liver MRI scans at 7 T, utilizing an eight‐channel parallel transmission system for phase shimming. B0 mapping and Fourier phase‐encoded dual refocusing echo acquisition mode (PE‐DREAM) multichannel B1+ mapping were performed during breath‐holds at expiration. Prospectively undersampled golden‐angle pseudo‐spiral k‐space data were acquired under free breathing, enabling retrospective respiratory binning using self‐gating. Post‐binning, the simultaneous autocalibrating and k‐space estimation (SAKE) algorithm was employed for interpolation of a center of k‐space area, prior to estimation of receive coil sensitivity maps. Image reconstruction was performed on expiration‐phase data using compressed sensing, optimizing image quality by evaluating various regularization factors and numbers of respiratory bins. Finally, N4BiasFieldCorrection was applied to the resulting images. Expiration‐phase image reconstruction using four bins and regularization factor values of 10−2.5 (1.50 mm) and 10−2.33 (1.35 mm) were found to optimize the tradeoff between sharpness, SNR, and artifacts. The optimized protocol facilitated clear visualization of the liver, blood vessels, and surrounding structures at isotropic resolutions of 1.50 and 1.35 mm in 3.5 min, without B1+ inhomogeneity effects in the shimmed liver region. A comparison between low‐resolution fully sampled free‐breathing (3.5 min) and breath‐hold (19 s) acquisitions demonstrated comparable sharpness and SNR. To compare the 7 T data with 3 T MRI, 3 T scans were performed for two participants. 3 T reconstructions were done similarly to 7 T, excluding N4BiasFieldCorrection. Scan‐specific regularization optimization was performed for fair comparison. Compared to 3 T, 7 T showed superior vascular contrast with inflow effects not observed at 3 T. Fold‐over artifacts were present in 3 T scans but were minor at 7 T. 3 T and 7 T provided comparable results, with a much higher RF channel count at 3 T. In conclusion, high‐resolution expiration‐phase liver imaging at 7 T with homogeneous signal can be successfully achieved using a phase‐shimmed, free‐breathing protocol with a golden‐angle pseudo‐spiral sampling pattern technique and respiratory self‐gating. This approach allows detailed anatomical depiction without the limitations of breath‐holding, representing a significant advancement in ultra‐high field abdominal MRI.Keywords
Funding Information
- International Society for Magnetic Resonance in Medicine
- Nederlandse Organisatie voor Wetenschappelijk Onderzoek
This publication has 81 references indexed in Scilit:
- MR angiography of the cerebral perforating arteries with magnetization prepared anatomical reference at 7T: Comparison with time‐of‐flightJournal of Magnetic Resonance Imaging, 2008
- Sparse MRI: The application of compressed sensing for rapid MR imagingMagnetic Resonance in Medicine, 2007
- Fast‐kzthree‐dimensional tailored radiofrequency pulse for reducedB1inhomogeneityMagnetic Resonance in Medicine, 2006
- Generalized self‐navigated motion detection technique: Preliminary investigation in abdominal imagingMagnetic Resonance in Medicine, 2006
- Perfusion Imaging of the Liver: Current Challenges and Future GoalsRadiology, 2005
- Sensitivity and Power Deposition in a High-Field Imaging ExperimentJournal of Magnetic Resonance Imaging, 2000
- Contrast agent-enhanced, free-breathing, three-dimensional coronary magnetic resonance angiographyJournal of Magnetic Resonance Imaging, 1999
- A nonparametric method for automatic correction of intensity nonuniformity in MRI dataIEEE Transactions on Medical Imaging, 1998
- Compensation for surface coil sensitivity variation in magnetic resonance imagingMagnetic Resonance Imaging, 1988
- Point Spread-Function, Line Spread-Function, and Modulation Transfer FunctionRadiology, 1969