Deep‐Learning‐Based Preprocessing for Quantitative Myocardial Perfusion MRI
Open Access
- 11 November 2019
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 51 (6) , 1689-1696
Abstract
Background: Quantitative myocardial perfusion cardiac MRI can provide a fast and robust assessment of myocardial perfusion status for the noninvasive diagnosis of myocardial ischemia while being more objective than visual assessment. However, it currently has limited use in clinical practice due to the challenging postprocessing required, particularly the segmentation.Purpose: To evaluate the efficacy of an automated deep learning (DL) pipeline for image processing prior to quantitative analysis.Study Type: Retrospective.Population: In all, 175 (350 MRI scans; 1050 image series) clinical patients under both rest and stress conditions (135/10/30 training/validation/test).Field Strength/Sequence: 3.0T/2D multislice saturation recovery T1‐weighted gradient echo sequence.Assessment: Accuracy was assessed, as compared to the manual operator, through the mean square error of the distance between landmarks and the Dice similarity coefficient of the segmentation and bounding box detection. Quantitative perfusion maps obtained using the automated DL‐based processing were compared to the results obtained with the manually processed images.Statistical Tests: Bland–Altman plots and intraclass correlation coefficient (ICC) were used to assess the myocardial blood flow (MBF) obtained using the automated DL pipeline, as compared to values obtained by a manual operator.Results: The mean (SD) error in the detection of the time of peak signal enhancement in the left ventricle was 1.49 (1.4) timeframes. The mean (SD) Dice similarity coefficients for the bounding box and myocardial segmentation were 0.93 (0.03) and 0.80 (0.06), respectively. The mean (SD) error in the RV insertion point was 2.8 (1.8) mm. The Bland–Altman plots showed a bias of 2.6% of the mean MBF between the automated and manually processed MBF values on a per‐myocardial segment basis. The ICC was 0.89, 95% confidence interval = [0.87, 0.90].Data Conclusion: We showed high accuracy, compared to manual processing, for the DL‐based processing of myocardial perfusion data leading to quantitative values that are similar to those achieved with manual processing.Level of Evidence: 3Technical Efficacy Stage: 1J. Magn. Reson. Imaging 2020;51:1689–1696.Keywords
Funding Information
- Engineering and Physical Sciences Research Council (EP/L015226/1)
- National Institute for Health Research
- Wellcome Trust DBT India Alliance (WT 088641/Z/09/Z)
This publication has 33 references indexed in Scilit:
- A Quantitative Pixel-Wise Measurement of Myocardial Blood Flow by Contrast-Enhanced First-Pass CMR Perfusion ImagingJACC: Cardiovascular Imaging, 2012
- Superior diagnostic performance of perfusion-cardiovascular magnetic resonance versus SPECT to detect coronary artery disease: The secondary endpoints of the multicenter multivendor MR-IMPACT II (Magnetic Resonance Imaging for Myocardial Perfusion Assessment in Coronary Artery Disease Trial)Journal of Cardiovascular Magnetic Resonance, 2012
- Assessment of distribution and evolution of Mechanical dyssynchrony in a porcine model of myocardial infarction by cardiovascular magnetic resonanceJournal of Cardiovascular Magnetic Resonance, 2012
- Quantitative analysis of transmural gradients in myocardial perfusion magnetic resonance imagesMagnetic Resonance in Medicine, 2011
- Training and accreditation in cardiovascular magnetic resonance in Europe: a position statement of the working group on cardiovascular magnetic resonance of the European Society of CardiologyEuropean Heart Journal, 2011
- Development of a universal dual-bolus injection scheme for the quantitative assessment of myocardial perfusion cardiovascular magnetic resonanceJournal of Cardiovascular Magnetic Resonance, 2011
- Quantification of myocardial perfusion by cardiovascular magnetic resonanceJournal of Cardiovascular Magnetic Resonance, 2010
- Cardiovascular magnetic resonance and PET-CT of left atrial paragangliomaJournal of Cardiovascular Magnetic Resonance, 2010
- Statistical validation of image segmentation quality based on a spatial overlap index1Academic Radiology, 2004
- Standardized Myocardial Segmentation and Nomenclature for Tomographic Imaging of the HeartCirculation, 2002