In vivo and in vitro repeatability of Hartmann-Shack aberrometry
Authors:
- Jens BührenJBJens Bühren
- Daniel GerhardtDGDaniel Gerhardt
- Thomas KohnenTKThomas Kohnen
- 1 December 2003
- journal article
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 29 (12) , 2295-2301
Abstract
To assess the in vivo and in vitro repeatability of objective refraction and higher-order aberrations (HOAs) measured by a commercially available Hartmann-Shack wavefront sensor. Department of Ophthalmology, Johann-Wolfgang-Goethe University, Frankfurt am Main, Germany. After pupil dilation of 40 myopic or myopic, astigmatic eyes of 20 patients, wavefront measurements were performed 6 times in each eye and in a test object provided by the manufacturer by 2 experienced examiners using a Hartmann-Shack wavefront sensor (Zywave, software version 3.21, Bausch & Lomb). The mean standard deviation (SD) and the coefficient of variation (CV) for sphere, cylinder, and each Zernike polynomial were computed for a 7.0 mm pupil diameter. Vector analysis was performed for the astigmatism. After the data were subdivided into 2 groups with 3 measurements in each, one measurement that best matched the subjective manifest refraction was chosen in each group and the difference between them was calculated. The mean SD (CV) was 0.15 diopter (D) (7%) for the sphere value of the predicted phoropter refraction and 0.16 D (22%) for astigmatism. Thirty-two eyes had an axis deviation of at least 10 degrees. Vector analysis revealed a mean SD of 0.24@109.8. Other results for mean SD and mean CV were as follows: total in vivo higher-order RMS, 0.097 microm, 13.4%; sphere in myopic test device, 0.034 D, 0.65%; sphere in hyperopic test object, 0.035 D, 0.72%. The difference between the 2 best-matched refractions was significantly different from zero (0.11 D, P<.001). The CV was significantly higher for HOAs than for the 2nd-order aberrations (defocus and astigmatism). Repeatability of Hartmann-Shack aberrometry by the Zywave wavefront sensor was not satisfactory, particularly for small amounts of HOAs. Under these conditions, aberrometry measurements should be repeated several times and outliers should be excluded in calculating the means.Keywords
This publication has 20 references indexed in Scilit:
- Wavefront guided ablationAmerican Journal of Ophthalmology, 2001
- History and Principles of Shack-Hartmann Wavefront SensingJournal of Refractive Surgery, 2001
- Grundlagen der wellenfrontgeführten refraktiven HornhautchirurgieDer Ophthalmologe, 2001
- Optics of aberroscopy and super visionJournal of Cataract & Refractive Surgery, 2001
- Clinical results of wavefront-guided laser in situ keratomileusis 3 months after surgeryJournal of Cataract & Refractive Surgery, 2001
- Principles of Hartmann-Snack AberrometryJournal of Refractive Surgery, 2000
- Supernormal vision, hypervision, and customized corneal ablationJournal of Cataract & Refractive Surgery, 2000
- Bivariate analysis of surgically induced regular astigmatism. Mathematical analysis and graphical displayOphthalmic and Physiological Optics, 1999
- Aberrations and retinal image quality of the normal human eyeJournal of the Optical Society of America A, 1997
- Supernormal vision and high-resolution retinal imaging through adaptive opticsJournal of the Optical Society of America A, 1997