Determination of Staphylococcus Enterotoxin B Using a Flexible Aptamer-Based Biosensor
- 3 March 2023
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 23 (7) , 6530-6536
Abstract
We demonstrate a fully flexible micromachined cantilever-based aptasensor for sensitive and specific sensing of Staphylococcus Enterotoxin B (SEB). The proposed flexible cantilever was fabricated using parylene-C as surface passivation layers and poly(3,4-ethylenedioxythiophene)/polystyrene sulfonate (PEDOT:PSS) as strain gauge for characterization of resistance. A spring constant of prepared cantilever was measured to be 12 nN/μm together with a deflection sensitivity of 1.42×10 -3 /μm. With assembled 78-mer 5’-biotinylated aptamers on the sensing cantilever surface, the fully flexible aptasensor is capable of specific recognition SEB with a limit detection of 0.3 ng/mL. To evaluate the applicability of the proposed aptasensor, detections on raw milk spiked with SEB were implemented. The comparison indicates the prepared aptasensor could be qualified for SEB recognition in food contaminants detections, and the fully flexible cantilever-based sensors have tremendous potential for applications in food safety evaluation.Keywords
Funding Information
- Natural Science Foundation of Shanxi Province (202103021224206)
- National Natural Science Foundation of China (61704158)
- Shanxi “1331 Project” Key Subjects Construction
This publication has 17 references indexed in Scilit:
- Design and fabrication of a flexible MEMS-based electro-mechanical sensor array for breast cancer diagnosisJournal of Micromechanics and Microengineering, 2015
- Aptamer-based biosensors for biomedical diagnosticsThe Analyst, 2014
- Nucleic Acid Aptamers: New Methods for Selection, Stabilization, and Application in Biomedical ScienceBiomolecules & Therapeutics, 2013
- Ultrasensitive and selective homogeneous sandwich immunoassay detection by Surface Enhanced Raman Scattering (SERS)The Analyst, 2012
- A Single-Stranded DNA Aptamer That Selectively Binds to Staphylococcus aureus Enterotoxin BPLOS ONE, 2012
- Cantilever-like micromechanical sensorsReports on Progress in Physics, 2011
- Cantilever biosensorsThe Analyst, 2008
- Polymeric cantilever-based biosensors with integrated readoutApplied Physics Letters, 2006
- Detection of Staphylococcal Enterotoxin B via Biomolecular Interaction Analysis Mass SpectrometryApplied and Environmental Microbiology, 2003
- Spectral surface plasmon resonance biosensor for detection of staphylococcal enterotoxin B in milkInternational Journal of Food Microbiology, 2002