Performance of a ventilated‐façade system under fire conditions: An experimental investigation
- 7 June 2020
- journal article
- research article
- Published by Wiley in Fire and Materials
- Vol. 44 (6) , 776-792
Abstract
Summary: During a fire event, ventilated facade systems may contribute to external fire spreading to the upper floors of a building via the facade, thus representing a significant risk. In this frame, the performance of a typical ventilated façade system under fire conditions is experimentally investigated, using a full‐scale compartment‐facade test rig. Two alternative façade configurations are examined and comparatively assessed, namely a plain façade (PF) and a ventilated façade (VF) system. Emphasis is given on the estimation of the thermal characteristics of the developed Externally Venting Flames (EVF) and the thermal boundary conditions developing on the façade's exposed surface. An extensive set of sensors was installed at the interior of the fire compartment, the façade systems and the exterior of the test configurations. Analysis of the experimental data suggests that even though gaseous combustion products managed to penetrate the air cavity of the VF system, no consistent flaming conditions were established. On the unexposed face of both PF and VF systems, temperatures remained constantly below 180°C throughout the duration of both fire tests. The Eurocode correlations are assessed against the obtained experimental data; certain parameters, such as EVF length, width and centreline temperature, are found to be under‐estimated by the Eurocode methodology.Keywords
Funding Information
- ‘‘Fire-Facts’’ project in the frame of the ARISTEIA action
- ELISSA: Energy Efficient Lightweight-Sustainable-Safe-Steel Construction (609086)
- MeeFS: Multifunctional Energy Efficient Façade System for Building Retrofitting (285411)
This publication has 37 references indexed in Scilit:
- Computer-simulation study on fire behaviour in the ventilated cavity of ventilated façade systemsMATEC Web of Conferences, 2013
- Fire spread modes and performance of fire stops in vented façade constructions – overview and standardization of test methodsMATEC Web of Conferences, 2013
- Experimental study on flame height and temperature profile of buoyant window spill plume from an under-ventilated compartment fireInternational Journal of Heat and Mass Transfer, 2012
- The Effect of Fuel Quantity and Location on Small Enclosure FiresJournal of Fire Protection Engineering, 2007
- Influence of gypsum board type (X or C) on real fire performance of partition assembliesFire and Materials, 2006
- Critical considerations on the use of a bi-directional probe in heat release measurementsFire and Materials, 2005
- Ventilated facades energy performance in summer cooling of buildingsSolar Energy, 2003
- Fire Safety in Green or Sustainable Buildings: Application of the Fire Engineering Approach in Hong KongArchitectural Science Review, 2003
- Fire-performance of a ventilated facade insulated with a B2-classified rigid polyurethane foamFire and Materials, 1986
- Momentum implications for buoyant diffusion flamesCombustion and Flame, 1983