Bacterial risk reduction by improved donor arm disinfection, diversion and bacterial screening
- 27 November 2006
- journal article
- review article
- Published by Wiley in Transfusion Medicine
- Vol. 16 (6) , 381-396
Abstract
summary The Interventions of improved donor arm disinfection, diversion and bacterial screening have been implemented by blood services and shown to have substantial benefit. The major source of bacterial contamination is donor arm derived. Blood services are now introducing best practice donor arm disinfection techniques.Diversion has been shown to substantially reduce bacterial contamination in the order of 40–88%. Diversion, together with improved donor arm disinfection, has shown to improve the percentage of reduction in contamination from 47% to 77%. Residual contamination levels after the Introduction of diversion and improved donor arm disinfection may be in the order of 30–40%. Numerous countries have now implemented screen testing programmes for platelet concentrates, which are the major source of bacterial transfusion transmission.Pathogen reduction systems have been developed and are under development. At present, concerns remain with these systems regarding cost, process control, ability to inactivate high titres of viruses, killing of bacterial spores, product damage, genotoxicity and mutagenicity.The interventions of diversion, improved donor arm disinfection and bacterial screen testing are currently available, As such they can be implemented now to increase blood safety with no associated patient risk.Keywords
This publication has 108 references indexed in Scilit:
- The Clearance Mechanism of Chilled Blood PlateletsCell, 2003
- Transfusion medicine: looking to the futureThe Lancet, 2003
- Evaluation of an automated culture systemfor detecting bacterial contamination of platelets: an analysis with 15 contaminating organismsTransfusion, 2001
- Inhibition of cytokine accumulation and bacterial growth during storage of platelet concentrates at 4° C with retention of in vitro functional activityTransfusion, 1997
- Automatic volumetric capillary cytometry for counting white cells in white cell‐reduced plateletpheresis componentsTransfusion, 1997
- A prospective microbiologic surveillance program to detect and prevent the transfusion of bacterially contaminated plateletsTransfusion, 1993
- Strategies for the avoidance of bacterial contamination of blood componentsTransfusion, 1993
- Sepsis associated with transfusion of red cells contaminated with Yersinia enterocoliticaTransfusion, 1990
- Evaluation of the buffy-coat smear for rapid detection of bacteremia1981
- The photodynamic action of riboflavine on erythrocytesLife Sciences, 1977