Importance of Electrode Selection and Number in Reconstructing Standard Twelve Lead Electrocardiograms
Open Access
- 25 May 2023
- journal article
- research article
- Published by MDPI AG in Biomedicines
- Vol. 11 (6) , 1526
Abstract
Many clinical and consumer electrocardiogram (ECG) devices collect fewer electrodes than the standard twelve-lead ECG and either report less information or employ algorithms to reconstruct a full twelve-lead signal. We assessed the optimal electrode selection and number that minimizes redundant information collection while maximizing reconstruction accuracy. We employed a validated deep learning model to reconstruct ECG signals from 250 different patients in the PTB database. Different numbers and combinations of electrodes were removed from the ECG before reconstruction to measure the effect of electrode inclusion on reconstruction accuracy. The Left Leg (LL) electrode registered the largest drop in average reconstruction accuracy, from an of 0.836 when the LL was included to 0.737 when excluded. Additionally, we conducted a correlation analysis to identify leads that behave similarly. We demonstrate that there exists a high correlation between leads I, II, aVL, aVF, V4, V5, and V6, which all occupy the bottom right quadrant in an ECG axis interpretation, and likely contain redundant information. Based on our analysis, we recommend the prioritization of electrodes RA, LA, LL, and V3 in any future lead collection devices, as they appear most important for full ECG reconstruction.
Keywords
This publication has 21 references indexed in Scilit:
- An Empirical Comparison of Model Validation Techniques for Defect Prediction ModelsIEEE Transactions on Software Engineering, 2017
- ECG monitoring leads and special leadsIndian Pacing and Electrophysiology Journal, 2016
- Root mean square error (RMSE) or mean absolute error (MAE)? – Arguments against avoiding RMSE in the literatureGeoscientific Model Development, 2014
- Electrocardiographic Systems With Reduced Numbers of Leads—Synthesis of the 12-Lead ECGIEEE Reviews in Biomedical Engineering, 2014
- Ambulatory Cardiac Monitoring for Discharged Emergency Department Patients with Possible Cardiac ArrhythmiasWestern Journal of Emergency Medicine, 2014
- ECG Patch Monitors for Assessment of Cardiac Rhythm AbnormalitiesProgress in Cardiovascular Diseases, 2013
- 12-lead Holter electrocardiographyHerzschrittmachertherapie + Elektrophysiologie, 2013
- PCA-Based ECG Lead ReconstructionBiomedical Engineering / Biomedizinische Technik, 2013
- A novel mobile transtelephonic system with synthesized 12-lead ECGIEEE Transactions on Information Technology in Biomedicine, 2004
- Fundamental differences between the standard 12-lead electrocardiograph and the modified (Mason--Likar) exercise lead systemEuropean Heart Journal, 1987