A Promising Solution to Enhance the Sensocompatibility of Biosensors in Continuous Glucose Monitoring Systems
Open Access
- 1 March 2013
- journal article
- research article
- Published by SAGE Publications in Journal of Diabetes Science and Technology
- Vol. 7 (2) , 455-464
Abstract
Background: Continuous glucose monitors (CGMs) measure glucose in real time, making it possible to improve glycemic control. A promising technique involves glucose sensors implanted in subcutaneous tissue measuring glucose concentration in interstitial fluid. A major drawback of this technique is sensor bioinstability, which can lead to unpredictable drift and reproducibility. The bioinstability is partly due to sensor design but is also affected by naturally occurring subcutaneous inflammations. Applying a nonbiofouling coating to the sensor membrane could be a means to enhancing sensocompatibility. Methods: This study evaluates the suitability of a polyethylene-glycol-based coating on sensors in CGMs. Methods used include cross hatch, wet paper rub, paper double rub, bending, hydrophilicity, protein adsorption, biocompatibility, hemocompatibility, and glucose/oxygen permeability testing. Results: Results demonstrate that coating homogeneity, adhesion, integrity, and scratch resistance are good. The coating repels lysozyme and bovine serum albumin, and only a low level of fibrin and blood platelet adsorption to the coating was recorded when testing in whole human blood. Cytotoxicity, irritation, sensitization, and hemolysis were assessed, and levels suggested good biocompatibility of the coating in subcutaneous tissue. Finally, it was shown that the coating can be applied to cellulose acetate membranes of different porosity without changing their permeability for glucose and oxygen. Conclusions: These results suggest that the mechanical properties of the coating are sufficient for the given application, that the coating is effective in preventing protein adsorption and blood clot formation on the sensor surface, and that the coating can be applied to membranes without hindering their glucose and oxygen transport.Keywords
This publication has 33 references indexed in Scilit:
- Severe hypoglycemia symptoms, antecedent behaviors, immediate consequences and association with glycemia medication usage: Secondary analysis of the ACCORD clinical trial dataBMC Endocrine Disorders, 2012
- Comparison of Modified Chandler, Roller Pump, and Ball Valve Circulation Models forIn VitroTesting in High Blood Flow Conditions: Application in Thrombogenicity Testing of Different Materials for Vascular ApplicationsInternational Journal of Biomaterials, 2012
- Effect of intensive glucose lowering treatment on all cause mortality, cardiovascular death, and microvascular events in type 2 diabetes: meta-analysis of randomised controlled trialsBMJ, 2011
- Acute consequences of hypoglycaemia in diabetic patientsDiabetes & Metabolism, 2010
- Surface‐modified nanoparticles as a new, versatile, and mechanically robust nonadhesive coating: Suppression of protein adsorption and bacterial adhesionJournal of Biomedical Materials Research Part A, 2008
- Emerging biomedical sensing technologies and their applicationsIEEE Sensors Journal, 2003
- Carbon paste electrode incorporated with cobalt(II) octaethoxyphthalocyanine for the amperometric detection of hydrogen peroxideElectroanalysis, 1995
- Continuous in vivo monitoring in diabetes: the subcutaneous glucose concentrationActa Anaesthesiologica Scandinavica, 1995
- Screen printed glucose electrodes based on platinised carbon particles and glucose oxidaseAnalytica Chimica Acta, 1993
- Subcutaneous glucose monitoring by means of electrochemical sensors: fiction or reality?Journal of Biomedical Engineering, 1992