Initial Validation and Clinical Experience with 3D Optical-Surface-Guided Whole Breast Irradiation of Breast Cancer
Open Access
- 1 February 2012
- journal article
- research article
- Published by SAGE Publications in Technology in Cancer Research & Treatment
- Vol. 11 (1) , 57-68
Abstract
We had introduced 3D optical surface-guided radiotherapy (SGRT) of the breast cancer (BC). We then initiated the feasibility, accuracy, and precision studies of stereovision in detection of any breast displacement through the course of treatment for total thirty breasts undertaken whole breast irradiation (WBI). In the SGRT, CT-based plan data were parsed into an in-house computer program through which the reference surfaces were generated in 3D video format. When patients were positioned on treatment Tables, real-time stereovisions were rapidly acquired while the live surface tracking shown steady thorax motion. The real-time surface images were automatically aligned with the reference surface and detected shape and location changes of the breast were online corrected through the Table and beam adjustments. Accumulated dose to each patient was computed according to the frequency distribution of the measured breast locations during beam on time. Application of SGRT had diminished large skin-marking errors of >5-mm and daily breast-setup errors of >10-mm that occurred on half of cases. Accuracy (mean) and precision (two standard deviations) of the breast displacements across the tangential field edges in the (U, V) directions were improved from (−0.5 ± 8.8, 2.2 ± 10.8) mm in conventional setup to (0.4 ± 4.6, 0.7 ± 4.4) mm in the final position while intra-fractional motion contributed only (0.1 ± 2.8, 0.0 ± 2.2) mm in free breathing. Dose uniformity and coverage to targets had both been increased by up to 10% and the lung or heart intersections have been decreased by half of those volumes if they were irradiated at the initial positions. SGRT of BC appears to be feasible regardless of skin tones, as fast as a snapshot for 3D imaging, and very accurate and precise for daily setup of flexible breast targets. Importantly, the technique allows us to verify the breast shape and position during beam-on time.Keywords
This publication has 32 references indexed in Scilit:
- Effects of Interfractional Motion and Anatomic Changes on Proton Therapy Dose Distribution in Lung CancerInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2008
- American College of Radiology Appropriateness Criteria® on Conservative Surgery and Radiation: Stages I and II Breast CarcinomaJournal of the American College of Radiology, 2008
- Practice Guideline for the Breast Conservation Therapy in the Management of Invasive Breast CarcinomaJournal of the American College of Surgeons, 2007
- Practice Guideline for the Management of Ductal Carcinoma In-Situ of the Breast (DCIS)Journal of the American College of Surgeons, 2007
- Towards a Noninvasive Intracranial Tumor Irradiation Using 3D Optical Imaging and Multimodal Data RegistrationInternational Journal of Biomedical Imaging, 2007
- Accurate calibration of a stereo‐vision system in image‐guided radiotherapyMedical Physics, 2006
- Clinical experience with a 3D surface patient setup system for alignment of partial-breast irradiation patientsInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2006
- Twenty-Year Follow-up of a Randomized Trial Comparing Total Mastectomy, Lumpectomy, and Lumpectomy plus Irradiation for the Treatment of Invasive Breast CancerNew England Journal of Medicine, 2002
- Twenty-Year Follow-up of a Randomized Study Comparing Breast-Conserving Surgery with Radical Mastectomy for Early Breast CancerNew England Journal of Medicine, 2002
- Twenty-Five-Year Follow-up of a Randomized Trial Comparing Radical Mastectomy, Total Mastectomy, and Total Mastectomy Followed by IrradiationNew England Journal of Medicine, 2002