ECG sonification to support the diagnosis and monitoring of myocardial infarction
Open Access
- 19 February 2020
- journal article
- research article
- Published by Springer Nature in Journal on Multimodal User Interfaces
- Vol. 14 (2) , 207-218
Abstract
This paper presents the design and evaluation of four sonification methods to support monitoring and diagnosis in Electrocardiography (ECG). In particular we focus on an ECG abnormality called ST-elevation which is an important indicator of a myocardial infarction. Since myocardial infarction represents a life-threatening condition it is of essential value to detect an ST-elevation as early as possible. As part of the evaluated sound designs, we propose two novel sonifications: (i) Polarity sonification, a continuous parameter-mapping sonification using a formant synthesizer and (ii) Stethoscope sonification, a combination of the ECG signal and a stethoscope recording. The other two designs, (iii) the water ambience sonification and the (iv) morph sonification, were presented in our previous work about ECG sonification (Aldana Blanco AL, Steffen G, Thomas H (2016) In: Proceedings of Interactive Sonification Workshop (ISon). Bielefeld, Germany). The study evaluates three components across the proposed sonifications (1) detection performance, meaning if participants are able to detect a transition from healthy to unhealthy states, (2) classification accuracy, that evaluates if participants can accurately classify the severity of the pathology, and (3) aesthetics and usability (pleasantness, informativeness and long-term listening). The study results show that the polarity design had the highest accuracy rates in the detection task whereas the stethoscope sonification obtained the better score in the classification assignment. Concerning aesthetics, the water ambience sonification was regarded as the most pleasant. Furthermore, we found a significant difference between sound/music experts and non-experts in terms of the error rates obtained in the detection task using the morph sonification and also in the classification task using the stethoscope sonification. Overall, the group of experts obtained lower error rates than the group of non-experts, which means that further training could improve accuracy rates and, particularly for designs that rely mainly on pitch variations, additional training is needed in the non-experts group.Keywords
Funding Information
- Deutscher Akademischer Austauschdienst (57129429)
- Deutsche Forschungsgemeinschaft (“CITEC” (EXC 277))
This publication has 15 references indexed in Scilit:
- Cardiac electrophysiology: normal and ischemic ionic currents and the ECGAdvances in Physiology Education, 2017
- Continuous sonification enhances adequacy of interactions in peripheral process monitoringInternational Journal of Human-Computer Studies, 2016
- Diagnosis and treatment of pericarditisHeart, 2015
- Acute myocardial ischemia: Cellular mechanisms underlying ST segment elevationJournal of Electrocardiology, 2014
- Interpretation of the Low-Voltage ECGAACN Advanced Critical Care, 2014
- Managing alarm fatigue in cardiac careProgress in Pediatric Cardiology, 2012
- Real-Time Detection of Myocardial Infarction by Evaluation of ST-Segment in Digital ECGJournal of Medical Imaging and Health Informatics, 2011
- Audio spectrum and sound pressure levels vary between pulse oximetersCanadian Journal of Anesthesia/Journal canadien d'anesthésie, 2006
- Heart Rate Sonification: A New Approach to Medical DiagnosisLeonardo, 2004
- A dynamical model for generating synthetic electrocardiogram signalsIEEE Transactions on Biomedical Engineering, 2003