Embedding Time-Limited Laboratory Orders Within Computerized Provider Order Entry Reduces Laboratory Utilization*
Authors:
- Natalie M. PagelerNPNatalie M. Pageler
- Deborah FranzonDFDeborah Franzon
- Christopher A. LonghurstCLChristopher A. Longhurst
- Matthew WoodMWMatthew Wood
- Andrew Y. ShinASAndrew Y. Shin
- Eloa S. AdamsEAEloa S. Adams
- Eric WidenEWEric Widen
- David N. CornfieldDCDavid N. Cornfield
- 1 May 2013
- journal article
- research article
- Published by Wolters Kluwer Health in Pediatric Critical Care Medicine
- Vol. 14 (4) , 413-419
Abstract
To test the hypothesis that limits on repeating laboratory studies within computerized provider order entry decrease laboratory utilization. Cohort study with historical controls. A 20-bed PICU in a freestanding, quaternary care, academic children's hospital. This study included all patients admitted to the pediatric ICU between January 1, 2008, and December 31, 2009. A total of 818 discharges were evaluated prior to the intervention (January 1, 2008, through December 31, 2008) and 1,021 patient discharges were evaluated postintervention (January 1, 2009, through December 31, 2009). A computerized provider order entry rule limited the ability to schedule repeating complete blood cell counts, chemistry, and coagulation studies to a 24-hour interval in the future. The time limit was designed to ensure daily evaluation of the utility of each test. Initial analysis with t tests showed significant decreases in tests per patient day in the postintervention period (complete blood cell counts: 1.5 ± 0.1 to 1.0 ± 0.1; chemistry: 10.6 ± 0.9 to 6.9 ± 0.6; coagulation: 3.3 ± 0.4 to 1.7 ± 0.2; p < 0.01, all variables vs. preintervention period). Even after incorporating a trend toward decreasing laboratory utilization in the preintervention period into our regression analysis, the intervention decreased complete blood cell counts (p = 0.007), chemistry (p = 0.049), and coagulation (p = 0.001) tests per patient day. Limits on laboratory orders within the context of computerized provider order entry decreased laboratory utilization without adverse affects on mortality or length of stay. Broader application of this strategy might decrease costs, the incidence of iatrogenic anemia, and catheter-associated bloodstream infections.Keywords
This publication has 19 references indexed in Scilit:
- Regional Variations in Diagnostic PracticesThe New England journal of medicine, 2010
- Variations In The Longitudinal Efficiency Of Academic Medical CentersHealth Affairs, 2004
- The Implications of Regional Variations in Medicare Spending. Part 2: Health Outcomes and Satisfaction with CareAnnals of Internal Medicine, 2003
- The Implications of Regional Variations in Medicare Spending. Part 1: The Content, Quality, and Accessibility of CareAnnals of Internal Medicine, 2003
- A randomized trial of a computer-based intervention to reduce utilization of redundant laboratory testsThe American Journal of Medicine, 1999
- Do We Know What Inappropriate Laboratory Utilization Is?JAMA, 1998
- Contaminant Blood Cultures and Resource UtilizationJAMA, 1991
- Medical Technology — A Different View of the Contentious Debate over CostsNew England Journal of Medicine, 1979
- Use of Laboratory Tests and PharmaceuticalsJAMA, 1973
- Nosocomial AnemiaJAMA, 1973