Respiration-Averaged CT for Attenuation Correction in Canine Cardiac PET/CT
Authors:
- Ting-Yim LeeTLTing-Yim Lee
- R. Glenn WellsRWR. Glenn Wells
Open Access
- 1 May 2007
- journal article
- research article
- Published by Society of Nuclear Medicine in Journal of Nuclear Medicine
- Vol. 48 (5) , 811-818
Abstract
Heart disease is a leading cause of death in North America. With the increased availability of PET/CT scanners, CT is now commonly used as a transmission source for attenuation correction. Because of the differences in scan duration between PET and CT, respiration-induced motion can create inconsistencies between the PET and CT data and lead to incorrect attenuation correction and, thus, artifacts in the final reconstructed PET images. This study compared respiration-averaged CT and 4-dimensional (4D) CT for attenuation correction of cardiac PET in an in vivo canine model as a means of removing these inconsistencies. Methods: Five dogs underwent respiration-gated cardiac 18F-FDG PET and 4D CT. The PET data were reconstructed with 3 methods of attenuation correction that differed only in the CT data used: The first method was single-phase CT at either end-expiration, end-inspiration, or the middle of a breathing cycle; the second was respiration-averaged CT, which is CT temporally averaged over the entire respiratory cycle; and the third was phase-matched CT, in which each PET phase is corrected with the matched phase from 4D CT. After reconstruction, the gated PET images were summed to produce an ungated image. Polar plots of the PET heart images were generated, and percentage differences were calculated with respect to the phase-matched correction for each dog. The difference maps were then averaged over the 5 dogs. Results: For single-phase CT correction at end-expiration, end-inspiration, and mid cycle, the maximum percentage differences were 11% ± 4%, 7% ± 3%, and 5% ± 2%, respectively. Conversely, the maximum difference for attenuation correction with respiration-averaged CT data was only 1.6% ± 0.7%. Conclusion: Respiration-averaged CT correction produced a maximum percentage difference 7 times smaller than that obtained with end-expiration single-phase correction. This finding indicates that using respiration-averaged CT may accurately correct for attenuation on respiration-ungated cardiac PET.Keywords
This publication has 13 references indexed in Scilit:
- Respiratory gating of cardiac PET data in list-mode acquisitionEuropean Journal of Nuclear Medicine and Molecular Imaging, 2006
- Physical evaluation of CT scan methods for radiation therapy planning: comparison of fast, slow and gating scan using the 256-detector row CT scannerPhysics in Medicine & Biology, 2006
- Rigid-body transformation of list-mode projection data for respiratory motion correction in cardiac PETPhysics in Medicine & Biology, 2005
- Four‐dimensional (4D) PET/CT imaging of the thoraxMedical Physics, 2004
- 4D-CT imaging of a volume influenced by respiratory motion on multi-slice CTMedical Physics, 2004
- X-ray-based attenuation correction for positron emission tomography/computed tomography scannersSeminars in Nuclear Medicine, 2003
- Gated fluorine 18 fluorodeoxyglucose positron emission tomography: determination of global and regional left ventricular function and myocardial tissue characterizationJournal of Nuclear Cardiology, 2003
- PET-CT Evaluation of 2-Deoxy-2-[18F]Fluoro-D-Glucose Myocardial Uptake: Effect of Respiratory MotionMolecular Imaging and Biology, 2003
- Assessment of myocardial viability by positron emission tomographyNuclear Medicine Communications, 2002
- Real-time system for respiratory-cardiac gating in positron tomographyIEEE Transactions on Nuclear Science, 1998