Abstract
This paper introduces an alternative implementation of the traditional LC filter, called hybrid LC filter (HLCF). The construction described in this paper contains two foil windings that integrate inductance and capacitance into one unit. The main aspects of the HLCF design are considered. The experimental data show that the device proposed here can be used, instead of traditional LC filters, as an alternative solution for the mitigation of the adverse effects of the pulse-width modulation (PWM).

This publication has 14 references indexed in Scilit: