Influence of Underfilling on Breast Implant Deflation
Authors:
- Francoise Roudot-ThoravalFRFrancoise Roudot-Thoraval
- Dale E. CollinsDCDale E. Collins
- Yvon RauloYRYvon Raulo
- Jean P. BaruchJBJean P. Baruch
- 1 December 1997
- journal article
- research article
- Published by Wolters Kluwer Health in Plastic and Reconstructive Surgery
- Vol. 100 (7) , 1740-1744
Abstract
The authors report a series of 407 patients with a total of 709 saline breast implants (average follow-up, 7.1 years). In this retrospective series, the overall deflation rate was 6.6 percent (47 of 709). Initial comparison of the deflation rates for smooth (8.8 percent) versus textured (1.8 percent) implants suggested a significant difference between the implant types. However, further analysis of the data revealed that smooth implants had a longer average follow-up period and tended to have lower fill volumes. These data were re-examined using Kaplan-Meier survival analysis plots, which corrected for differences in follow-up times, and log rank tests performed to determine significance. Implant type was found to have a nonsignificant association with rupture rate. In contrast, the percent fill (implant fill volume per minimum recommended fill volume X 100) was significantly associated with the spontaneous ruptures; a mean difference of 13.9 percent (89.2 percent versus 103.1 percent) was found between the series of deflated implants and the nondeflated implants (p < 0.0001). These data suggest that underfilling is a major cause of deflation. (Plast. Reconstr. Surg. 100: 1740, 1997.)Keywords
This publication has 14 references indexed in Scilit:
- Saline inflatable prostheses: 14 years' experienceAesthetic Plastic Surgery, 1993
- Clinical Experience with Heyer-Schulte Inflatable Implants in Breast AugmentationPlastic and Reconstructive Surgery, 1986
- Postmastectomy breast reconstruction with an inflatable prosthesisBritish Journal of Surgery, 1984
- INFLATABLE BREAST IMPLANTSPlastic and Reconstructive Surgery, 1983
- The Mechanical Properties of Breast ProsthesesAnnals of Plastic Surgery, 1981
- Mammary Implant Shell FailureAnnals of Plastic Surgery, 1980
- Late Leakage of Inflatable Silicone Breast ProsthesesPlastic and Reconstructive Surgery, 1980
- Experiences with inflatable implantsAesthetic Plastic Surgery, 1979
- One Preventable Cause of Spontateous Deflation of Inflatable Mammary ProsthesesPlastic and Reconstructive Surgery, 1979
- RUPTURE OF INFLATED BREAST IMPLANTS IN CLOSED COMPRESSION CAPSULOTOMYPlastic and Reconstructive Surgery, 1977