Investigation on Time-to-Peak Feature Insensitive to Liftoff Effect for Pulsed Eddy Current Evaluation
- 18 November 2019
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 69 (7) , 5064-5071
Abstract
The influence of liftoff variation on the peak value and time-to-peak feature of pulsed eddy current (PEC) signals is investigated in this work by simulations and experiments. Firstly, PEC response is analytically modelled via Fourier transform for simulations. In an alternative way, PEC response is formulated with Laplace transform. Using an approximation of Laplace transform based PEC formulation, the physics is discovered that liftoff distance only changes the amplitude of PEC responses rather than shifts the position of peak heights. Secondly, simulations were implemented, and the results demonstrate that the time-to-peak feature is insensitive to liftoff variation, around one fourth of the peak value. Finally, the experimental results agree well with those from the simulations, which validates the physics that the time-to-peak feature is insensitive to liftoff effect.Keywords
Funding Information
- Fundamental Research Funds for the Central Universities (2019XKQYMS35)
- Priority Academic Program Development of Jiangsu Higher Education Institutions for funding this study
This publication has 27 references indexed in Scilit:
- Assessment of wall thinning in insulated ferromagnetic pipes using the time-to-peak of differential pulsed eddy-current testing signalsNDT & E International, 2012
- Ferromagnetic material pulsed eddy current testing signal modeling by equivalent multiple-coil-coupling approachNDT & E International, 2011
- Analytical modeling for transient probe response in pulsed eddy current testingNDT & E International, 2009
- Improved immunity to lift-off effect in pulsed eddy current testing with two-stage differential probesRussian Journal of Nondestructive Testing, 2008
- Thickness measurement of non-magnetic plates using multi-frequency eddy current sensorsNDT & E International, 2007
- Transient Eddy-Current Driver Pickup Probe Response Due to a Conductive PlateIEEE Transactions on Magnetics, 2006
- Transient and harmonic eddy currents: Lift-off point of intersectionNDT & E International, 2006
- Reduction of lift-off effects for pulsed eddy current NDTNDT & E International, 2005
- A feature extraction technique based on principal component analysis for pulsed Eddy current NDTNDT & E International, 2003
- Lift-off and tilt effects on eddy current sensor measurements: a 3-D finite element studyThe European Physical Journal Applied Physics, 2002