Beat-to-beat blood pressure measurement in patients with atrial fibrillation: a step towards personalized managemen
Authors:
Open Access
- 1 May 2021
- journal article
- research article
- Published by Institute of Cardio Technics - INCART in Journal of Arrhythmology
- Vol. 28 (1) , 23-32
Abstract
Aim. Blood pressure (BP) determination in atrial fibrillation (AF) patients remains challenging due to its high inter-measurement variability. The novel methodology of precise beat-to-beat BP determination may be used to guide the hypotensive therapy selection and adjustment, but along with that provides additional opportunity for the investigation of hemodynamics in patients with chronic AF.Material and method. The study sample consisted of 60 patients with the main diagnosis of grade II-III arterial hypertension; 30 of those were on sinus rhythm and 30 had chronic non-valvular AF. In all patients HR was within the limits recommended for left ventricular ejection fraction of >40%. Beat-to-beat systolic, diastolic, and pulse BP (SBP, DBP, and PBP, respectively) assessment at each heart beat within 15 minute interval was performed with “Kardiotekhnika-SAKR” system (NAO “Incart”, St.Petersburg, Russia).Keywords
This publication has 11 references indexed in Scilit:
- Blood pressure measurement in atrial fibrillationJournal Of Hypertension, 2019
- Accuracy of automated blood pressure measurements in the presence of atrial fibrillation: systematic review and meta-analysisJournal of Human Hypertension, 2019
- Comparing volume-clamp method and intra-arterial blood pressure measurements in patients with atrial fibrillation admitted to the intensive or medium care unitJournal of Clinical Monitoring and Computing, 2017
- Auscultatory versus oscillometric blood pressure measurement in patients with atrial fibrillation and arterial hypertensionBMC Cardiovascular Disorders, 2017
- 2016 ESC Guidelines for the management of atrial fibrillation developed in collaboration with EACTSEuropean Heart Journal, 2016
- Blood Pressure in Patients With Atrial Fibrillation: Part 1––MeasurementThe Journal of Clinical Hypertension, 2016
- Automated blood pressure measurement in atrial fibrillationJournal Of Hypertension, 2013
- Automated blood pressure measurement in atrial fibrillationJournal Of Hypertension, 2012
- Continuous non-invasive blood pressure monitoring using concentrically interlocking control loopsComputers in Biology and Medicine, 2006
- A SpiroarteriocardiorhythmographBiomedical Engineering, 2006