A Lead‐Selective Membrane Electrode Based Upon a Phosphorylated Hexahomotrioxacalix[3]Arene
- 1 December 2007
- journal article
- research article
- Published by Wiley in Journal of the Chinese Chemical Society
- Vol. 54 (6) , 1535-1542
Abstract
Solvent extraction of a mixture of PbII, MnII, FeIII, CoII, NiIIand CdIIin aqueous perchlorate medium by a phosphorylated hexahomotrioxacalix[3]arene (calix‐3) in dichloromethane shows a significant selectivity towards lead ions. The ligand can also be incorporated into a membrane to provide a new lead ion‐selective electrode (PbII‐ISE). A plasticized PVC membrane containing 30% PVC, 53.5%ortho‐nitrophenyloctylether (NPOE), 4.5% sodium tetraphenylborate (NaTPB) and 12% ionophore was directly coated on a graphite rod. This sensor gave a good Nernstian response of 29.7 ± 0.7 mV decade−1over a concentration range of 1 × 10−8– 1 × 10−4M of lead ions, independent of pH in the range 3‐7, with a detection limit of 0.4 × 10−8M. The dynamic response time of the electrode to achieve a steady potential was very fast and found to be less than 7 s. The selectivity relative to Ag+, NH4+, Li+, Na+, K+, Ca2+, Sr2+, Ba2+, Mn2+, Fe2+, Co2+, Ni2+, Cu2+, Zn2+, Cd2+, Fe3+, La3+, Sm3+, Dy3+, Er3+, Y3+and Th4+was examined. The electrode exhibits adequate stability with good reproducibility (with a slope of 29.6 ± 1.5 mV for 8 weeks). The characteristics of the sensor are compared with those of a tetraphosphorylated calix[4]arene (calix‐4) based PbII‐ISE, reported recently. The electrode was successfully used as an indicator electrode for a potentiometric titration of a lead solution using a standard solution of EDTA. The applicability of the sensor for lead ion measurements in various synthetic samples was also investigated.Keywords
This publication has 25 references indexed in Scilit:
- Nafion-coated uranyl selective electrode based on calixarene and tri-n-octyl phosphine oxideSensors and Actuators B: Chemical, 2003
- Lower-RIM Polyphosphorylated Calix[4]arenes. Their Use as Extracting Agents for Thorium (IV) and Europium (III) IonsPhosphorus, Sulfur, and Silicon and the Related Elements, 2003
- Silver Ion-Selective Electrodes Using π-Coordinate Calix[4]arene Derivatives as Soft Neutral CarriersAnalytical Chemistry, 2000
- Lead-Selective Electrodes Based on Calixarene Phosphine Oxide DerivativesAnalytical Chemistry, 1999
- Phosphorus-containing calixarenesRussian Chemical Reviews, 1998
- SOLVENT EXTRACTION OF THE RARE-EARTH METAL IONS BY A CONE-SHAPED CALDC[4]ARENE SUBSTITUTED AT THE LOWER RTM BY FOUR -CH2P(O)Ph2LIGANDSSolvent Extraction and Ion Exchange, 1997
- Calcium-selective electrode based on a calix[4]arene tetraphosphine oxideTalanta, 1996
- Calixarenes, Macrocycles with (Almost) Unlimited PossibilitiesAngewandte Chemie International Edition, 1995
- Characteristics of a europium-selective electrode based on a calix[4]arene tetraphosphine oxideAnalytical Proceedings including Analytical Communications, 1995
- Calixarenes. 4. The synthesis, characterization, and properties of the calixarenes from p-tert-butylphenolJournal of the American Chemical Society, 1981