Intraoperative End-Tidal Carbon Dioxide Levels and Derived Calculations Correlated with Outcome in Trauma Patients
Authors:
- James G. TyburskiJTJames G. Tyburski
- Susan M. KubinecSKSusan M. Kubinec
- Karyn M. WarsowKWKaryn M. Warsow
- Howard C. LarkyHLHoward C. Larky
- Suzanne R. WilsonSWSuzanne R. Wilson
- Thomas SchermerhornTSThomas Schermerhorn
- 1 October 1996
- journal article
- Published by Wolters Kluwer Health in The Journal of Trauma: Injury, Infection, and Critical Care
- Vol. 41 (4) , 606-611
Abstract
To determine the relationship between the prognosis of seriously injured patients requiring emergency surgery and intraoperative end-tidal CO2 variables and "excess Pco2." Retrospective chart review of 100 seriously injured patients admitted to Detroit Receiving Hospital and requiring major surgery (mortality rate of 40%). Standard intraoperative monitoring, including continuous capnography, plus arterial blood analyses every 15 to 30 minutes during surgery. After resuscitation for 45 to 90 minutes, 11 patients had a systolic blood pressure < 100 mm Hg and, of these patients, 10 (91%) died. Of the remaining 89 patients, mortality rates were 53% (16/30), with an end-tidal CO2 of 22 mm Hg or less, versus 24% (14/59) with an end-tidal CO2 of 23 mm Hg or more (p = 0.011). An arterial to end-tidal Pco2 difference of 13 mm Hg or more after resuscitation was associated with an increased mortality rate (50% (20/34 vs. 18% (20/55)) (p < 0.005). The mortality rate was particularly high, with a final arterial to end-tidal Pco2 difference of 12 mm Hg or more (73% (30/41) versus 17% (10/59) (p < 0.001). A final Paco2 excess (i.e., the amount by which the Paco2 was higher than expected from the bicarbonate) > 1.0 mm Hg was also associated with an increased mortality rate ((62% (33/53) vs. 15% (7/47)) (p < 0.001). Values derived from the end-tidal CO2 and the excess Pco2 should be monitored intraoperatively in critically injured patients. Efforts should be made to improve cardiac output and adjust ventilation to maintain an end-tidal Pco2 of 25 mm Hg or more, an arterial to end-tidal CO2 difference of 12 mm Hg or less, and an excess Paco2 of 1.0 mm Hg or less.Keywords
This publication has 13 references indexed in Scilit:
- Intraoperative end-tidal carbon dioxide values and derived calculations correlated with outcomeCritical Care Medicine, 1995
- The end‐tidal carbon dioxide detector Assessment of a new method to distinguish oesophageal from tracheal intubationAnaesthesia, 1990
- End-Tidal Carbon Dioxide Monitoring During Cardiopulmonary ResuscitationJAMA, 1989
- End-Tidal Carbon Dioxide Concentration during Cardiopulmonary ResuscitationNew England Journal of Medicine, 1988
- Esophageal IntubationAnesthesia & Analgesia, 1986
- Intraoperative events diagnosed by expired carbon dioxide monitoring in childrenCanadian Journal of Anesthesia/Journal canadien d'anesthésie, 1986
- DEADSPACE AND THE SINGLE BREATH TEST FOR CARBON DIOXIDE DURING ANAESTHESIA AND ARTIFICIAL VENTILATIONBritish Journal of Anaesthesia, 1984
- Quantitative Displacement of Acid-Base Equilibrium in Metabolic AcidosisAnnals of Internal Medicine, 1967
- THE EXPIRED CARBON DIOXIDE AS A CONTINUOUS GUIDE OF THE PULMONARY AND CIRCULATORY SYSTEMS DURING ANESTHESIA AND SURGERYThe Journal of Thoracic and Cardiovascular Surgery, 1961
- Respiratory dead space and arterial to end-tidal CO2 tension difference in anesthetized manJournal of Applied Physiology, 1960