Denoising diffusion-based MRI to CT image translation enables automated spinal segmentation
Authors:
- Robert GrafRGRobert Graf
- Joachim SchmittJSJoachim Schmitt
- Sarah SchlaegerSSSarah Schlaeger
- Hendrik Kristian MöllerHMHendrik Kristian Möller
- Vasiliki Sideri-LampretsaVSVasiliki Sideri-Lampretsa
- Anjany SekuboyinaASAnjany Sekuboyina
- Sandro Manuel KriegSKSandro Manuel Krieg
- Benedikt WiestlerBWBenedikt Wiestler
- Bjoern MenzeBMBjoern Menze
- Daniel RueckertDRDaniel Rueckert
- Jan Stefan KirschkeJKJan Stefan Kirschke
Preprint
Abstract
Background: Automated segmentation of spinal MR images plays a vital role both scientifically and clinically. However, accurately delineating posterior spine structures presents challenges. Methods: This retrospective study, approved by the ethical committee, involved translating T1w and T2w MR image series into CT images in a total of n=263 pairs of CT/MR series. Landmark-based registration was performed to align image pairs. We compared 2D paired (Pix2Pix, denoising diffusion implicit models (DDIM) image mode, DDIM noise mode) and unpaired (contrastive unpaired translation, SynDiff) image-to-image translation using "peak signal to noise ratio" (PSNR) as quality measure. A publicly available segmentation network segmented the synthesized CT datasets, and Dice scores were evaluated on in-house test sets and the "MRSpineSeg Challenge" volumes. The 2D findings were extended to 3D Pix2Pix and DDIM. Results: 2D paired methods and SynDiff exhibited similar translation performance and Dice scores on paired data. DDIM image mode achieved the highest image quality. SynDiff, Pix2Pix, and DDIM image mode demonstrated similar Dice scores (0.77). For craniocaudal axis rotations, at least two landmarks per vertebra were required for registration. The 3D translation outperformed the 2D approach, resulting in improved Dice scores (0.80) and anatomically accurate segmentations in a higher resolution than the original MR image. Conclusion: Two landmarks per vertebra registration enabled paired image-to-image translation from MR to CT and outperformed all unpaired approaches. The 3D techniques provided anatomically correct segmentations, avoiding underprediction of small structures like the spinous process.Keywords
All Related Versions
This publication has 17 references indexed in Scilit:
- Unsupervised Medical Image Translation With Adversarial Diffusion ModelsIEEE Transactions on Medical Imaging, 2023
- VerSe: A Vertebrae labelling and segmentation benchmark for multi-detector CT imagesMedical Image Analysis, 2021
- MRI-based Synthetic CT in the Detection of Structural Lesions in Patients with Suspected Sacroiliitis: Comparison with MRIRadiology, 2021
- A review on medical imaging synthesis using deep learning and its clinical applicationsJournal of Applied Clinical Medical Physics, 2020
- Contrastive Learning for Unpaired Image-to-Image Translation2020
- SpineParseNet: Spine Parsing for Volumetric MR Image by a Two-Stage Segmentation Framework With Semantic Image RepresentationIEEE Transactions on Medical Imaging, 2020
- Deep learning–based MR‐to‐CT synthesis: The influence of varying gradient echo–based MR images as input channelsMagnetic Resonance in Medicine, 2019
- Generative models: an upcoming innovation in musculoskeletal radiology? A preliminary test in spine imagingEuropean Radiology Experimental, 2018
- Whole-Body MR Imaging in the German National Cohort: Rationale, Design, and Technical BackgroundRadiology, 2015
- UK Biobank: Current status and what it means for epidemiologyHealth Policy and Technology, 2012